N6019-2V1 1/98VISTA-100COMMERCIAL FIRE AND BURGLARYPARTITIONED SECURITY SYSTEMwith SCHEDULINGINSTALLATION INSTRUCTIONSandPROGRAMMING GUIDE

Página 2

xHow To Use This ManualThis manual is written to accommodate both the new and the experienced installer ofADEMCO products. The information contained i

Página 3

18-1SECTION 18The Mechanics Of Programming••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Using Data Field Program Mode♦ System and C

Página 4 - Table of Contents

VISTA-100 Installation Instructions18-2Entering Data Field Programming ModeEnter Data Field Program Mode using one of these methods:• Press both the ✴

Página 5

Section 18 - The Mechanics of Programming18-3• In either of the above cases, simply re-enter ✴ plus the correct field number.SUMMARY OF DATA FIELD PR

Página 6

VISTA-100 Installation Instructions18-4you have finished entering the partition-specific fields, enter the number of any globalfield.Repeat Steps 1 an

Página 7

19-1SECTION 19Zone Type Definitions••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Zone Number Designations♦ Zone Type Definitions•••

Página 8

VISTA-100 Installation Instructions19-2Type 02: Entry/Exit #2 BurglaryThis zone type provides a secondary entry delaywhenever the zone is faulted if y

Página 9 - List of Figures

Section 19 - Zone Type Definitions19-3response. Initial short detection causes 6-secondsmoke detector power reset. A subsequent shortdetection withi

Página 10 - How To Use This Manual

VISTA-100 Installation Instructions19-4

Página 11 - 00 INSTALLER CODE

20-1SECTION 20Zone Index/Zone Type Defaults••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Zone Index♦ Zone Type Defaults••••••••••••

Página 12 - General Description

VISTA-100 Installation Instructions20-2Zone Type DefaultsThe following tables detail the zone type defaults for zones on the VISTA-100:Zone # Zone Typ

Página 13 - Wireless Expansion

xiConventions Used in This ManualBefore you begin using this manual, it is important that you understand the meaning of thefollowing symbols (icons).N

Página 14

21-1SECTION 21 Data Field Descriptions••••••••••••••••••••••••••••••••••••••••••••••••The following is a description of all data fields provided by t

Página 15

VISTA-100 Installation Instructions21-2*13 BELL 1 TIMEOUT (partition-specific) [04]|This field defines the length of time Bell Output 1 and the keyp

Página 16

Section 21 - Data Field Descriptions21-3*22 KEYPAD PANIC ENABLES (partition-specific) [001]||995 996 999Enter 1 to enable the appropriate keypad pani

Página 17

VISTA-100 Installation Instructions21-429 QUICK ARM (partition-specific) [0]If you enable Quick Arm, the user can arm the burglary system in AWAY, S

Página 18 - Planning a Partitioned System

Section 21 - Data Field Descriptions21-5Enter the downloading phone number, up to 17 digits (the same as in fields *33 and*34). Do not fill unused sp

Página 19 - Common Lobby Logic

VISTA-100 Installation Instructions21-6*44 RING DETECTION COUNT[00]|This field is only applicable if you are using a 4285/4286 VIP Module and/or if yo

Página 20 - COMMON LOBBY

Section 21 - Data Field Descriptions21-7option 3, fire alarms and supervisories go to the primary number only; all reports go tothe secondary number.*

Página 21

VISTA-100 Installation Instructions21-8*88 BURG. ALARM COMM. DELAY (partition-specific)[0]Enter 0 if you want no delay on burglary alarm communicatio

Página 22

Section 21 - Data Field Descriptions21-91*23 CROSS ZONING PAIR TWO||||Enter the second pair of zones that must both be faulted within a 5-minute perio

Página 23

VISTA-100 Installation Instructions21-101*33 TOUCHTONE W/ROTARY BACKUP[0]Enter 1 to enable rotary backup dialing if the communicator is not successfu

Página 24 - In This Section

VISTA-100 Installation Instructions1-xiiSECTION 1General Description••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Overview♦

Página 25 - Cross Zoning

Section 21 - Data Field Descriptions21-111*53 DISABLE DOWNLOAD CALLBACK[0]Enter 1 to disable the callback requirement for downloading. Enter 0 to requ

Página 26 - Call Waiting Defeat Logic

VISTA-100 Installation Instructions21-12command "57." (Refer to Section 22: #93 Menu Mode Programming and “Programmingwith #80 Scheduling Me

Página 27

Section 21 - Data Field Descriptions21-13suppressed during the closing window in order to prevent false alarms if the user armsthe system, then re-ent

Página 28 - Installing The Control

VISTA-100 Installation Instructions21-142*24 DISPLAY TROUBLES OF OTHER PARTITIONS[0]Enter 1 if you want troubles that occur on other partitions to be

Página 29

Section 21 - Data Field Descriptions21-153*21 MAX # OF DIALER RETRIES[8]Enter a number from 1 to 8 to set the maximum number of retries to each teleph

Página 30

VISTA-100 Installation Instructions21-163*60 BELL 2 & AUX RELAY TIMEOUT[00,00]|| Bell 2 Aux. Rly.Use this field to define the length of time Bel

Página 31

22-1SECTION 22#93 Menu Mode Programming••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦#93 Main Menu Options♦ Zone Programming♦ Storin

Página 32 - Installing The Keypads

VISTA-100 Installation Instructions22-2pre-programmed).SEQUENTIAL LEARN?0=No 1=YesOn the Sequential Learn Menu, you can perform thesefunctions:• Progr

Página 33 - Figure 5-2

Section 22 - #93 Menu Mode Programming22-3#93 Menu Mode Key Commands#93 Enters Menu Mode. ✴ Serves as ENTER key. Press to have keypad accept the

Página 34 - Mounting the Keypads

VISTA-100 Installation Instructions22-4ENTER ZN NO.000 = QUIT 010Zone 010 entered ↑ Enter the 3-digit zone number that you want to program. Asan examp

Página 35 - Programming Remote Keypads

Section 1 - General Description1-xiii• Individually assignable to bell outputs and/or aux. relayULWireless devices are not permitted in UL Commercial

Página 36 - Basic Hardwired Zones 001-008

Section 22 - #93 Menu Mode Programming22-5Press ✴ to continue.010 BELL/RLY SEL 0Assign each zone to activate either one or both bell outputsand/or

Página 37 - DETECTOR

VISTA-100 Installation Instructions22-6Figure 22-1: RF Transmitter Loop Designations010 LEARN S/N?1 = YES, 0 = NO 1If the device’s serial number has

Página 38 - Figure 6.2

Section 22 - #93 Menu Mode Programming22-7010 INPUT S/N A022-4064The system will enroll the serial number of the first deviceheard and will displa

Página 39 - Zone 6 Tamper Configuration

VISTA-100 Installation Instructions22-8To enroll serial numbers in Sequential Mode, take the following steps:1. Enter Data Field Programming Mode by e

Página 40

Section 22 - #93 Menu Mode Programming22-9If the first zone number you enter does not have all of the aboveattributes, the system will search its data

Página 41

VISTA-100 Installation Instructions22-10At any time during this step, you may press ✴ on the keypad or the upper left button of theprogram tool if yo

Página 42 - (Zones 9 - 87)

Section 22 - #93 Menu Mode Programming22-11To enter report codes, take the following steps:Enter Program Mode by entering [Installer Code] + 8 0 0 0.

Página 43 - #16 gauge 2400 feet

VISTA-100 Installation Instructions22-12double-digit entry) and press ✴ . The second digit will bethe ID (second) digit of the Alarm report code for

Página 44 - Power-Up Procedure

Section 22 - #93 Menu Mode Programming22-13enter other system report codes, enter 0 (NO) and press ✴ tocontinue.System Group 3 CodesSYSTEM GROUP #3?1

Página 45

VISTA-100 Installation Instructions22-14• Each description can be composed of a combination of words (up to 3) that are selectedfrom a vocabulary of 2

Página 46 - Polling Loop Supervision

VISTA-100 Installation Instructions1-xiv• Certain system options are selectable for each partition, such as Entry/Exit Delay andsubscriber account num

Página 47

Section 22 - #93 Menu Mode Programming22-15Find the descriptor words you want to use in the fixed-word vocabulary list later in thissection. In this e

Página 48 - Wireless Zone Expansion

VISTA-100 Installation Instructions22-2a. Press [#], followed by the 2-digit code that represents the first letter you would like todisplay (e.g., 65

Página 49

Section 22 - #93 Menu Mode Programming22-3A cursor will be present at the extreme left of the first line (over the first asterisk). Press6 to move the

Página 50 - 1 2 3 4 5

VISTA-100 Installation Instructions22-4ALPHA DESCRIPTOR VOCABULARYUse this vocabulary list to enter alpha descriptors. To select a word, press [#] fo

Página 51 - House ID Sniffer Mode

Section 22 - #93 Menu Mode Programming22-5Device ProgrammingUse this menu to program keypads, receivers, and relay modules.From Data Field Programming

Página 52 - 5700 Series Transmitter Setup

VISTA-100 Installation Instructions22-6SOUND OPTIONIf you entered device type 1 (alpha keypad), this prompt willappear. You can program keypads indiv

Página 53

Section 22 - #93 Menu Mode Programming22-7START (STT) The START programming determines when and under what conditionsthe device will be activated. Th

Página 54 - 5800 Series Transmitter Setup

VISTA-100 Installation Instructions22-8B)1. ZONE TYPE/SYSTEM OPERATION (ZT). Instead of using aRESTORE ZONE LIST, you can select a specific zone (resp

Página 55

Section 22 - #93 Menu Mode Programming22-902 START: ZN TYPEYou can use a Zone Type/System Operation instead of or inaddition to an Event/Zone List com

Página 56

VISTA-100 Installation Instructions22-1001 FIRE BELL?1 = YES 0 = NOIf this relay is on a supervised 4204CF module, you can use itas an additional fir

Página 57

Section 1 - General Description1-xvAuxiliary RelayProvides a built-in Form C relay which can be used for one of the following purposes:• Alarm activat

Página 58 - Relay Outputs

Section 22 - #93 Menu Mode Programming22-11001 Zn to Delete?000=QUIT 000Enter each zone number to be deleted from the Zone List,pressing ✴ af

Página 59 - 121110987654321

VISTA-100 Installation Instructions22-12Relay Voice Descriptors and Custom Word Substitutes VocabularyWord IndexAir...116Ala

Página 60

Section 22 - #93 Menu Mode Programming22-1301 ENTER INDEX #Enter the 3-digit substitute word index number from the RelayVoice Descriptors and Custom

Página 61

23-1SECTION 23Scheduling Options••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Introduction to Scheduling♦ Time Window Definitions♦

Página 62 - 4285/4286 VIP Module

VISTA-100 Installation Instructions23-2friendly menus (#80, #81 & #83 modes), explained in detail in this section. These menustake you step by ste

Página 63 - Wiring the VIP Module

Section 23 - Scheduling Options23-3Time-DrivenEventsBy using time windows, the system can automatically activate and de-activate relays at predetermin

Página 64 - Programming the VIP Module

VISTA-100 Installation Instructions23-4Mon Tue Wed Thu Fri Sat Sun HolOp/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl01/04 01/04 01/04 01/04 01/05 02/

Página 65

Section 23 - Scheduling Options23-5Open/Close DefinitionsOpening and closing windows are controlled by schedules that you define. There are threetypes

Página 66

VISTA-100 Installation Instructions23-6Programming with #80 Scheduling Menu ModeYou can use #80 Scheduling Menu Mode to program most of the scheduling

Página 67 - Programming

Section 23 - Scheduling Options23-7There are 5 sets of scheduling menus, as shown below. To select a menu set, enter 1 at adisplayed main menu prompt.

Página 68

VISTA-100 Installation Instructions1-xviOptional Backup DialerSupports use of 5140DLM Backup Dialer for connecting to a second supervised telephonelin

Página 69

VISTA-100 Installation Instructions23-8Time Windows Definitions WorksheetThe system provides 20 time windows that you can define with start and stop t

Página 70 - J2 Trigger Outputs

Section 23 - Scheduling Options23-9Time Window programming and display the “Quit?” prompt.Enter 0 at the “Quit?” prompt toreturn to the main menu choi

Página 71

VISTA-100 Installation Instructions23-10Open/Close Schedules programming. You will see the “Quit?”prompt.Enter 0 at the “Quit?” prompt toreturn to the

Página 72

Section 23 - Scheduling Options23-11Holiday Definitions & Schedule WorksheetYou can define up to 16 holidays for the system. Each holiday can be a

Página 73 - 5140LED Indicator Module

VISTA-100 Installation Instructions23-12When you have programmed all holidays, enter 00 at the“HOLIDAY NUMBER?” prompt to exit the Holiday menus.Time-

Página 74

Section 23 - Scheduling Options23-13Relay commandsAction CodeActionSpecifier01 Relay On Relay #02 Relay Off Relay #03 Relay Close for 2 seconds Rel

Página 75 - 7720 WIRING DIAGRAM

VISTA-100 Installation Instructions23-14Open/Close WindowsActivation time 3 (During) is the only valid choice for these functions:Action CodeActionSpe

Página 76 - PANIC ALARM

Section 23 - Scheduling Options23-15Timed Events?1 Yes 0 = No 0Enter 1 to program timed events using relay outputs.TIMED EVENT # ?01-20, 00=Q

Página 77 - Direct Wire Downloading

VISTA-100 Installation Instructions23-16time that has been stored for the window is displayed. Pressthe ✴ to continue.01 Active time?

Página 78

Section 23 - Scheduling Options23-17Access Sched. ?1 Yes 0 = No 0Enter 1 to program access schedules.If no limitations apply, enter 0.ACCESS S

Página 79 - External Sounders

Section 1 - General Description1-xviiCross-Zoning CapabilityHelps prevent false alarms by preventing a zone from going into alarm unless its designate

Página 80 - Programming the Bell Outputs

VISTA-100 Installation Instructions23-18Partition/Windows Mon Tue Wed Thu Fri Sat SunStart Time HH:MMStop Time HH:MM3Disarm WindowStart Time HH:MMStop

Página 81 - (Model 610-7)

Section 23 - Scheduling Options23-19Programming Temporary SchedulesOnly users with an authority level of manager or higher can program temporary sched

Página 82 - Auxiliary Relay

VISTA-100 Installation Instructions23-20#83 User Scheduling Menu ModeThe system provides up to 20 "timers" that allow the end user to contro

Página 83 - Four-Wire Detector Circuit

Section 23 - Scheduling Options23-21Enter 0 to put the schedule in effect for one week only.Press ✴ to accept the entry. The system will quit UserSc

Página 84 - Section 14- Auxiliary Relay

24-1SECTION 24System Communication••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ A Successful Transmission♦ Reporting Formats♦ Loadi

Página 85 - Dialer Outputs

VISTA-100 Installation Instructions24-2The following table describes each format in greater detail:3+1 and 4+1 StandardFormatsComprised of a 3- or 4-d

Página 86 - Dialer Operation

Section 24 - System Communications24-3ADEMCO Contact ID Reporting takes the following format: CCCC QEEE GG ZZZwher

Página 87 - Section 15- Dialer Outputs

VISTA-100 Installation Instructions24-41234 5155 1555 1 (Acct #1234, with alarms on channels 9 and 12)LIMITATIONS• ADEMCO High Speed reporting provide

Página 88 - Event Log Options

Section 24 - System Communications24-5TABLE OF CONTACT ID EVENT CODESCode Definition110 Fire Alarm111 Smoke Alarm*113 Water Flow Alarm121 Duress122 Si

Página 89 - Programming Event Log Options

VISTA-100 Installation Instructions24-6COMMUNICATION DEFAULTS for LOW SPEED FORMAT (*94*80)*45 PRIMARY FORMAT 0 Ademco Low Speed*46 LOW SPEED FOR

Página 90 - Event Logging Procedures

2-1SECTION 2Planning a Partitioned System••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Theory of Partitioning♦ Setting Up a Partiti

Página 91

Section 24 - System Communications24-7COMMUNICATION DEFAULTS FOR ZONESZone #Low Speed1st 2ndExpress1st 2ndHigh Speed1st 2ndContact ID1st 2nd001 01 00

Página 92 - Section 16- Event Log Options

VISTA-100 Installation Instructions24-8COMMUNICATION DEFAULTS FOR ZONES (cont’d)Zone #Low Speed1st 2ndExpress1st 2ndHigh Speed1st 2ndContact ID1st 2nd

Página 93 - Final Power-Up Procedure

Section 24 - System Communications24-9COMMUNICATION DEFAULTS FOR ZONES (cont’d)Zone #Low Speed1st 2ndExpress1st 2ndHigh Speed1st 2ndContact ID1st 2nd6

Página 94 - Backup Power Calculations

VISTA-100 Installation Instructions24-10COMMUNICATION DEFAULTS FOR ZONES (cont’d)Zone #Low Speed1st 2ndExpress1st 2ndHigh Speed1st 2ndContact ID1st 2n

Página 95 - Cannot exceed 128MA

25-1SECTION 25Downloading Primer(Remote Downloading is not a UL Listed feature)••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Genera

Página 96

VISTA-100 Installation Instructions25-22. Enter [Installer code] + [#] + 5. The panel temporarily enables a ring count of 5 andsets the Download Callb

Página 97

Section 25 - Downloading Primer25-3• Set the real-time clock.Access SecurityAccess to the control panel from a remote location is protected against co

Página 98 - BATTERY SELECTION TABLE

VISTA-100 Installation Instructions25-4The connections between the control panel and the 4100SM are different from thoseshown in the 4100SM Installati

Página 99 - Section 17 – Final Power-Up

26-1SECTION 26Setting The Real-Time Clock••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Setting the Time and Da

Página 100 - The Mechanics Of Programming

VISTA-100 Installation Instructions26-2

Página 101 - Entry Errors

VISTA-100 Installation Instructions2-2(multiple access) can "log on" to one partition from another partition's keypad, providedthat pro

Página 102

27-1SECTION 27User Access Codes••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ User Codes and Levels of Authorit

Página 103 - #93 Menu Mode Programming

VISTA-100 Installation Instructions27-2Level 0: Installer (User 1)• Program this level in field *00 (default = 5-1-4-0). Select installer Open/Close r

Página 104 - Zone Type Definitions

VISTA-100 Installation Instructions27-2• Operator C (sometimes known as the Babysitter code) cannot disarm the system unlessthe system was armed with

Página 105

Section 27 - User Access Codes27-3Note that Open/Close reporting of Quick Arm is enabled if User 002 is enabled forOpen/Close reporting, and that Quic

Página 106

VISTA-100 Installation Instructions27-4User Number = 003Enter Auth. LevelEnter the level number as follows:1 = Master (arm, disarm, bypass, add, or mo

Página 107

Section 27 - User Access Codes27-5global arm options that you programmed for each partition towhich you granted the user access. For example:Part. 1 A

Página 108 - Zone Index/Zone Type Defaults

28-1SECTION 28Keypad Functions••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Arming Functions♦ Global Arming♦ A

Página 109 - Zone Type Defaults

VISTA-100 Installation Instructions28-2SYSTEM COMMANDSFUNCTION ACTIONDisplay FaultedZonesBefore arming, the system must be in the READY condition (all

Página 110 - Data Field Descriptions

Section 28 - Keypad Functions28-3• If, when you are disarming the system using a Global Disarm, any of the selectedpartitions has a condition that wou

Página 111

VISTA-100 Installation Instructions28-4Part. 1 A0T WHSEUser 01 Auth.=1G.The user's Open/Close report capability is shown by the periodfollowing

Página 112 - 995 996 999

iiRecommendations for Proper ProtectionThe Following Recommendations For The Location Of Fire And Burglary Detection Devices Help ProvideProper Covera

Página 113

Section 2 - Planning a Partitioned System2-3You cannot program a partition to "arm" the lobby unless you first program it to "affect&qu

Página 114

Section 28 - Keypad Functions28-5• Arming sequences that involve bypassing certain zones before arming.• Seldom-used but repeatable sequences.• Relay

Página 115 - Prm. Sec

VISTA-100 Installation Instructions28-6nn DEVICE IS OFFHIT 0=OFF , 1=ONVoice: "[voice descriptor] DEVICE nn ON/OFF. FOR [voicedescriptor] ON E

Página 116 - 95 96 99 Duress

29-1SECTION 29Testing The System••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Checkout Procedure for Hardwired Zones♦ Checkout Proc

Página 117 - [15 15 15 15]

VISTA-100 Installation Instructions29-2to which the zone is assigned should display the number of the faulted zone. Trippingfire and panic zones will

Página 118

Section 29 - Testing The System29-35. When you see the proper display on the keypad(s), the polling loop zones in the systemare functioning properly

Página 119

VISTA-100 Installation Instructions29-4• If you are using a single receiver, the keypad will beep three times to indicate that ithas received a signal

Página 120 - Alm Chck Byps O/C Systm Test

Section 29 - Testing The System29-5by the installer by entering [Installer Code] + [#] + 68 while the burglary portion of thesystem is disarmed. This

Página 121

VISTA-100 Installation Instructions29-6Burglary Walk-Test (Code + TEST 5)The Burglary Walk-Test causes the system to sound keypad beeps in response to

Página 122

Section 29 - Testing The System29-7Trouble ConditionsSupervisory MessagesA keypad display of “SUPV” accompanied by a zone number (001-087) and an alph

Página 123 - Bell 1 Bell 2

VISTA-100 Installation Instructions29-8• Fire trouble on any zone (zone response types 9, 16, 17, 18, 19)• Fire supervisory present (zone response typ

Página 124 - Bell 2 Aux

VISTA-100 Installation Instructions2-4Sequence #2:Office 1 Office 2 Lobby ActionUser #2:(Armed) Disarms DisarmsUser #1:Disarms (Disarmed) (No change)U

Página 125 - Bell 2 Aux. Rly

Section 29 - Testing The System29-9Contacting Technical SupportPLEASE!Before you call Technical Support, be sure you:• READ THE INSTRUCTIONS!• Check a

Página 126

VISTA-100 Installation Instructions29-10

Página 127

Appendix A-1APPENDIX ARegulatory Agency Statements••••••••••••••••••••••••••••••••••••••••••••••••UL Installation RequirementsThe following requiremen

Página 128 - Zone Programming

VISTA-100 Installation InstructionsAppendix A-2• If a secondary number is programmed, set the maximum number of dialer re-tries to 3, 4,or 5 in field

Página 129

Appendix A - Regulatory Agency StatementsAppendix A-3For Grade AA Service:• Follow the instructions for Grade A service, except use the 7920SE in plac

Página 130

VISTA-100 Installation InstructionsAppendix A-4"FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT"This equipment has been tested to FCC requ

Página 131 - Axxx-xxxx

Appendix A - Regulatory Agency StatementsAppendix A-5CANADIAN DEPARTMENT OF COMMUNICATIONS(DOC) STATEMENTNOTICEThe Canadian Department of Communicatio

Página 132

VISTA-100 Installation InstructionsAppendix A-6

Página 133 - Zone Number Entered

Appendix B-1APPENDIX BDIP Switch Tables••••••••••••••••••••••••••••••••••••••••••••••••

Página 135 - Report Code Programming

Section 2 - Planning a Partitioned System2-5Master Keypad Setup and OperationAlthough this system has 8 actual partitions, it provides an extra partit

Página 136

Appendix B - DIP Switch TablesAppendix B-3DIP SWITCH TABLES FOR POLLING LOOP DEVICES4275 PIRMIRRORDIPSHOWN SET FORID 10 (A)SIDE VIEW(UP)1234567UPDNPOS

Página 137

VISTA-100 Installation InstructionsAppendix B-4DIP SWITCH TABLES FOR 5700 RF SYSTEM WIRELESS DEVICESHOUSE ID (1 SHOWN)HOUSE ID (1 SHOWN)HOUSE ID (1 SH

Página 138 - Programming Alpha Descriptors

Appendix C-1APPENDIX CSummary of System Commands••••••••••••••••••••••••••••••••••••••••••••••••Event LoggingCommandsEvent Log Display = Code + [#] +

Página 139

VISTA-100 Installation InstructionsAppendix C-2SchedulingCommandsInstaller-Programmed Schedule Events = Installer Code + [#] + 80Temporary Schedule Ed

Página 140

Appendix D-1APPENDIX DSpecifications••••••••••••••••••••••••••••••••••••••••••••••••VISTA-100 CONTROLPhysical:18”H X 14.5”W X 4.3”DElectrical:Primary

Página 141 - ****DISARMED****

VISTA-100 Installation InstructionsAppendix D-2DIGITAL COMMUNICATORFormats Supported:ADEMCO High SpeedADEMCO 4+2 ExpressADEMCO Low SpeedADEMCO Contact

Página 142

Index-1Index••••••••••••••••••••••••••••••••••••••••••••••••1451 Enclosure, 4-41451 Transformer, 4-424-Hour Audible Alarm, 19-224-Hour Auxiliary Alarm

Página 143 - (For Adding Custom Words)

VISTA-100 Installation InstructionsIndex-2FFalse Alarm Reduction, 3-1FCC, A-4FCC Registration No, D-1Federal CommunicationsCommission (FCC) Statement,

Página 144 - Device Programming

IndexIndex-3TTamper Protection, 8-7Technical Support: Contact, 29-9Telephone Line Connections,15-1Temporary Schedule Worksheet,23-18Temporary Schedule

Página 145 - Relay Programming

VISTA-100 Installation InstructionsIndex-4

Página 146

VISTA-100 Installation Instructions2-6A Master keypad uses the same panic buttons as Partition 1. Master keypad panics are sent toPartition 1, and wi

Página 147

WARNING!THE LIMITATIONS OF THIS ALARM SYSTEMWhile this System is an advanced wireless security system, it does not offer guaranteed protection against

Página 148

Appendix-6We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and theirloved ones to learn about t

Página 149 - Zone List Programming

ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiariesand affiliates ("Sel

Página 150 - Relay Voice Descriptors

TRANSFORMERW/ENCLOSUREADEMCO No.1451(supplied)INPUT: 120VAC, 60HZ, 1.0A max. Connect to a dedicated circuit. See

Página 151 - CUSTOM WORD NO

165 Eileen Way, Syosset, New York, 11791Copyright © 1997 PITTWAY CORPORATION

Página 152 - RF Serial Number Clear Mode

3-1SECTION 3False Alarm Reduction Features••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Exit Error Logic and R

Página 153 - Scheduling Options

VISTA-100 Installation Instructions3-2• Exit Error by Zone (this is sent as a regular alarm if you are using ADEMCO High Speedformat)• Bypass reportsR

Página 154

Section 3 - False Alarm Reduction Features3-3• If an entry/exit zone is paired with an interior follower zone, be sure to enter theentry/exit zone as

Página 155 - Time Windows Definitions

VISTA-100 Installation Instructions3-4

Página 156

4-1SECTION 4Installing The Control••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Mounting the Control Cabinet♦ Installing the Cabine

Página 157 - Open/Close Definitions

VISTA-100 Installation Instructions4-2ULFor UL installations which are intended to provide certificated burglary service, refer to thespecial requirem

Página 158

iiiIn addition, we recommend that radio backup be used in a security system so that alarm signals canstill be sent to the alarm monitoring station in

Página 159

Section 4 - Installing The Control4-3Installing the Control's Circuit BoardTo install the control’s circuit board, take the following steps and r

Página 160 - Programming Time Windows

VISTA-100 Installation Instructions4-4Panel Earth Ground ConnectionsTo ground the panel, take the following steps:1. Connect the earth ground post ins

Página 161 - Daily Open/Close Worksheet

5-1SECTION 5Installing The Keypads••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Keypads That May Be Used♦ Wiring to the Keypads♦ Us

Página 162

VISTA-100 Installation Instructions5-2• The length of all wire runs combined must not exceed 2000 feet when unshielded quadconductor cable is used (10

Página 163 - Programming Holiday Schedules

Section 5 - Installing The Keypads5-3Figure 5-2. Using a Supplementary Power Supply for KeypadsMounting the KeypadsMount the keypads at a height that

Página 164 - Time-Driven Event Worksheet

VISTA-100 Installation Instructions5-45. When the proper “READY” message is displayed on the keypad(s) addressed at 00, 01, 02,and 03, the system is f

Página 165

6-1SECTION 6Basic Hardwired Zones 001-008••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Common Characteristics of Hardwired Zones 1-

Página 166 - Time-Driven Event Programming

VISTA-100 Installation Instructions6-2Wiring 2-Wire Smoke Detectors to Zones 1 and 2Zones 1 and 2 have the added capability of supporting 2-wire smoke

Página 167

Section 6 - Basic Hardwired Zones 001-0086-3Compatible 2-Wire Smoke DetectorsYou may use up to sixteen 2-wire smoke detectors each on zones 1 and 2. T

Página 168 - Access Control Schedules

VISTA-100 Installation Instructions6-4Figure 6-2. 4-Wire Smoke Detector Connections (Zones 1-8)2. Connect detectors (including heat detectors, if use

Página 169

ivTable of Contents••••••••••••••••••••••••••••••••••••••••••••••••RECOMMENDATIONS FOR PROPER PROTECTION...

Página 170

Section 6 - Basic Hardwired Zones 001-0086-5When you set it in this manner, the zone will trigger a trouble when the panel is disarmedand an alarm whe

Página 171

VISTA-100 Installation Instructions6-6Programming and Checkout of Hardwired ZonesYou must program each zone in order for it to become operational. To

Página 172 - #83 User Scheduling Menu Mode

7-1SECTION 72-Wire Polling Loop Expansion(Zones 9 - 87)••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Polling Loop Overview♦ Common

Página 173

VISTA-100 Installation Instructions7-2number or group is determined by the setting of DIP switches. Other devices have a built-inunique serial number

Página 174 - System Communication

Section 7 - 2-Wire Polling Loop Expansion7-3Figure 7-1. Polling Loop ConnectionsThe 4297 Polling Loop Extender may be used to provide additional poll

Página 175

VISTA-100 Installation Instructions7-4Figure 7-2a. Polling Loop Connections Using One 4297 Extender ModuleFigure 7-2b. Polling Loop Connections Usin

Página 176

Section 7 - 2-Wire Polling Loop Expansion7-5Polling Loop SupervisionA short on the polling loop is indicated by a trouble on its supervisory zone, and

Página 177

VISTA-100 Installation Instructions7-6Compatible Polling Loop Devices (cont’d)4275 Dual PIR • Dual-element PIR with built-in RPM(connects directly to

Página 178

8-1SECTION 8Wireless Zone Expansion••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Common Characteristics of Wireless Zones♦ Wireless

Página 179

VISTA-100 Installation Instructions8-25800 SeriesReceiver Zones5881L up to 85881M up to 165881H up to 875881EH up to 87 (use withUL864 installations)I

Página 180

Table of ContentsvFire Alarm Verification for Smoke Detectors...6-4Zone 6 Tamper Configu

Página 181

Section 8 - Wireless Zone Expansion8-3• For maximum range, install the RF receiver at least 10 feet from the control panel orany keypads to avoid inte

Página 182

VISTA-100 Installation Instructions8-4Installing the 5800TM ModuleYou will need to install this module only if you are using one or more 5827BD Wirele

Página 183

Section 8 - Wireless Zone Expansion8-55700 Series Transmitter SetupEach 5700 Series transmitter has DIP switches to set both the transmitter’s zone nu

Página 184 - Downloading Primer

VISTA-100 Installation Instructions8-6Zone Type Trans/Zone #Entry/Exit Burglary 1 through 47 *Perimeter Burglary 1 through 47 *Interior Burglary 1 thr

Página 185 - On-Line Control Functions

Section 8 - Wireless Zone Expansion8-7Compatible 5700 Series Transmitters (cont’d)Model Product Zone No. Description5775 PIR Detector 32-47 • Dual-ele

Página 186 - Access Security

VISTA-100 Installation Instructions8-8The supervision for a particular transmitter that may be carried off the premises (5801,5802MN) can be turned of

Página 187 - J2 CONNECTOR

Section 8 - Wireless Zone Expansion8-9Compatible 5800 Series Transmitters (cont’d)Model ProductProgram AsInput Type Description58025802CPPendant (Pers

Página 188 - Setting The Real-Time Clock

VISTA-100 Installation Instructions8-10Compatible 5800 Series Transmitters (cont’d)Model ProductProgram AsInput Type Description5827 Wireless Keypad H

Página 189

8-1SECTION 9Relay Outputs••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Relay Basics♦ Wiring the 4204 and 4204CF Relay Modules♦ Prog

Página 190 - User Access Codes

VISTA-100 Installation Instructions9-2Figure 9-1a: 4204 Relay ModuleSWITCH 4204 ADDRESS SETTINGSPOSITION ("—" means "OFF")0 1 2 3

Página 191

Table of ContentsviSection 13. EXTERNAL SOUNDERS... 13-1Ge

Página 192

Section 9-Relay Outputs9-3Figure 9-1b: 4204CF Relay Module3. When you are mounting them remotely, homerun each module back to the control. Thetable be

Página 193 - Master Oper B

VISTA-100 Installation Instructions9-4

Página 194

10-1SECTION 104285/4286 VIP Module••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Mounting the VIP Module♦ Wirin

Página 195 - To EXIT the User Edit Mode

VISTA-100 Installation Instructions10-2To mount the VIP Module, take the following steps:1. When the VIP Module is mounted inside the control cabinet,

Página 196 - Keypad Functions

Section 10-4285 VIP Module10-3ANSWERING MACHINESPEAKER VOLUMEADJUSTABLE ON4286 ONLY▲▲4285/4286PHONE MODULE123456 7YELLOW: TO DATA OUT (term. 14)NO CON

Página 197 - Global Arming

VISTA-100 Installation Instructions10-4

Página 198 - Hit 0-2 Hours

11-1SECTION 11Audio Alarm Verification (AAV) Unit••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ AAV Module Oper

Página 199 - Speed Key “D” (Macros)

VISTA-100 Installation Instructions11-2messages triggered during ongoing conversation will be held until either the AAV modulesignals that it is inact

Página 200 - 00=QUIT 01

Section 11 – Audio Alarm Verification (AAV) Unit11-31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16▲ONMODEL EAGLE SECURITY1241REFER TO AAV MODULEINSTRUC

Página 201 - HIT THE "*" KEY

VISTA-100 Installation Instructions11-4

Página 202 - Testing The System

Table of ContentsviiReport Code Programming...22-9Programmin

Página 203 - DISARMED Press

12-1SECTION 12J2 Trigger Outputs••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Remote Keypad Sounder Operation

Página 204

VISTA-100 Installation Instructions12-2Figure 12-1. J2 Pin Assignments and FunctionsRemote Keypad Sounder Operation and WiringYou can use an optional

Página 205 - Dialer Test

Figure 12-3. Remote Keyswitch WiringULIn Commercial Fire installations, mount the keyswitch next to a keypad. The keypad will providethe UL-required

Página 206

VISTA-100 Installation Instructions12-4Keyswitch Operation With Alarms Present:A momentary short across zone 7 will silence alarm bell and keypad soun

Página 207 - Armed Burglary System Test

Section 12 – J2 Trigger Outputs12-5If you use this feature, set program field 3*20 to 2, and connect the 5140LED module toJ2/OUT 1, 3, 4, 5, as shown

Página 208 - Trouble Conditions

VISTA-100 Installation Instructions12-6The fire and burglary/audible panic alarm triggers remain HIGH until a [User Code] + OFFis entered in all enabl

Página 209 - To the Installer

4.7K(NOTE)ZONE 1TB212345678910TB112345678910CONNECT TO POLLINGLOOP GROUND SCREWZONE 2ZONE 3ZONE 4ZONE 5FAULTCABINET GROUNDEARTH GROUNDSEE 7920SE INST.

Página 210

VISTA-100 Installation Instructions12-8Event Log Printer ConnectionsThe VISTA-100's event log can be printed on a local serial printer. If you u

Página 211

Section 12 – J2 Trigger Outputs12-9

Página 212 - Regulatory Agency Statements

13-1SECTION 13External Sounders••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Bell Circuit Supervision♦ Program

Página 213

Table of ContentsviiiTo Add an RF Key to an Existing User...27-6To DELETE a Mas

Página 214

VISTA-100 Installation Instructions13-2To unsupervise bell circuits, take the following steps:1. Cut the white jumpers W1 (for Bell 1) and/or W4 (for

Página 215 - Appendix A-4

Section 13 - External Sounders13-3ModelDescriptionSystem Sensor MASS121575 ADA Horn/StrobeSystem Sensor MA/SS-12 Horn/StrobeWheelock LS1-12-VFR Strobe

Página 216 - Appendix A-5

14-1SECTION 14Auxiliary Relay••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Relay Functions•••••••••••••••••••••••••••••••••••••••••

Página 217 - Appendix A-6

VISTA-100 Installation Instructions14-2Trouble/Supervisory Activation (3*61 = 0)You can program steady activation in response to any zone- or system-r

Página 218 - DIP Switch Tables

Section 14- Auxiliary Relay14-3

Página 219

15-1SECTION 15Dialer Outputs••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Dialer Outputs Available♦ Telephone Line Connections♦ Tel

Página 220 - Appendix B-3

VISTA-100 Installation Instructions15-2• To prevent the risk of shock, disconnect phone lines at telco jacks before servicing the panel.• If the commu

Página 221 - Appendix B-4

Section 15- Dialer Outputs15-3

Página 222 - Summary of System Commands

16-1SECTION 16Event Log Options••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ General Information♦ Event Log Printer Connections♦ Pr

Página 223

VISTA-100 Installation Instructions16-2123456789J2 CONNECTOR4142TR CABLE876543214100SM+ PWR- (GND)RXDnot usednot usednot usednot usedDTRRED BLUE WH

Página 224 - Specifications

ixList of Figures••••••••••••••••••••••••••••••••••••••••••••••••4-1. Installing the Lock...

Página 225 - 6139(R) REMOTE KEYPAD

Section 16- Event Log Options16-55. Exit Program Mode by pressing *99.NOTE: For more information about actual programming procedures, see Section 18:

Página 226

VISTA-100 Installation Instructions16-4ALL EVENT LOGTYPE CCC UUUDisplay shows all categories of events in chronological orderfrom most recent to oldes

Página 227

Section 16- Event Log Options16-5

Página 228

17-1SECTION 17Final Power-Up Procedure••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Connecting the AC Transformer♦ Backup Power Cal

Página 229

VISTA-100 Installation Instructions17-25. Replace the front cover of the enclosure and fasten it with the screws supplied.A few seconds after power is

Página 230 - WARNING!

Section 17 – Final Power-Up17-3Select one of the batteries (listed in the Battery Selection Table later in this section)which has a capacity greater t

Página 231 - Appendix-6

VISTA-100 Installation Instructions17-4Total Control Panel Load WorksheetsTo calculate the total current for the Aux. Power 1, Aux. Power 2, Bell 1 an

Página 232

Section 17 – Final Power-Up17-55. Enter the total pollingloop using valuescalculated in thepolling loopworksheet.POLLING LOOP Total CurrentStandby Ala

Página 233 - SUMMARY OF CONNECTIONS

VISTA-100 Installation Instructions17-6Capacity Formula Calc ValueStandbyCapacityTotal standby load x 24 or 60 hours x 1.1contingency factor (use tota

Página 234

Section 17 – Final Power-Up17-7