- 8 -
Field Function
Programmed Values[ ] = Table 1 Default Value
✱
75 RF XMTR LO BAT RST RPT CODE
|
[1,0]
✱
76 TEST RESTORE RPT CODE
|
[0,0]
DYNAMIC SIGNALING FIELD
✻
✻✻
✻
77
✱
77
DYNAMIC SIGNALING DELAY/
DYNAMIC SIGNALING PRIORITY
| [0, 0]
1st Entry (delay before switch CS reporting path)
0 = Redundant reporting
on dialer and LRR/IP
device
7 = 105 seconds
8 = 120 seconds
9 = 135 seconds
1 = 15 seconds #10 = 150 seconds
2 = 30 seconds #11 = 165 seconds
3 = 45 seconds #12 = 180 seconds
4 = 60 seconds #13 = 195 seconds
5 = 75 seconds #14 = 210 seconds
6 = 90 seconds #15 = 225 seconds
2nd Entry
0 = Primary Dialer Preferred Channel
1 = LRR/IP Preferred Channel
2 = LRR/IP reporting only
OUTPUT AND SYSTEM SETUP (
✱
80–
✱
92)
✱
80
✱
81
DEVICE PROGRAMMING MENU
MODE
ZONE LISTS MENU MODE
Program
✻
80 and
✻
81 only if Powerline Carrier Devices or
chime by zone are to be used. See procedure later in this
manual.
✱
83
ENHANCED SEQUENTIAL MODE See procedure later in this manual.
✱
84
ASSIGN ZONE VOICE DESCRIPTOR
See procedure later in this manual.
✱
85
RECORD CUSTOM VOICE
DESCRIPTOR
See procedure later in this manual.
✱
87
AUX FUNCTION/ 1-BUTTON PAGING
[0]
0 = Aux key performs defined function (macro);
1 = Aux key sends message to pager or voice message to follow me
system phone number.
If 1, you must also select an option 6-9 in field
✻
49 for the pager or
10-13 for the follow me system announcement.
✱
88
PAGER CHARACTERS
Up to 16 digits can be entered that will appear in front of the 7-digit
pager message sent by the control (either upon system event or upon
pressing AUX key [if programmed for paging]; see field
✻
87 and
✻
49
for other options regarding the paging feature). See the Installation
Instructions (fields
✻
87,
✻
88 and
✻
49) for full descriptions of the
paging feature. You do not need to fill all 16 digits (press [
✻
] to
advance to next field). To clear entries, enter
✻
88
✻
.
To enter “
✻
” = [#] + [11]; To enter “#” = [#] + 12]
To enter 2-second pause = [#] + [13] (some pagers require an
additional delay [pause] in order to receive the entire message)
✱
89
EVENT LOG 80% FULL RPT CODE
|
[0,0]