- 6 -
Field Function
Programmed Values [ ] = Table 1 Default Value
NOTES:
(1) If pager is enabled (Options 6-9 in Field *49) the end user cannot use the “Follow me”, and “Follow me” reminder features.
(2) LYNX reports system status as a voice message.
✱
49
CENTRAL STATION/PAGER
REPORTING/FOLLOW ME
[0]
0 = Disable (Backup report only)
** Pager Message
A 7-digit code (plus optional 16-digit prefix) is
sent to the pager consisting of a 3-digit event code,
followed by 00 and a 2-digit user or zone number.
See Installation Instructions for an explanation of
the pager code, which takes the following form:
AAAAAAAAAAAAAAAA-EEE-00NN
TO CENTRAL STA. PHONE No.
6 = All except Open/Close
7 = All reports
8 = All reports
9 = All except Open/Close
TO END USER PHONE No.
**
Alarms, Open/Close
‡
, Troubles
Alarms, Troubles
Alarms, Open/Close
‡
, Troubles
Open/Close
‡
‡
Will report users 0, 5-8 or wireless
arm/disarm button zones 26-33; all other
zones and users do not report
AAA… = optional 16-digits (see field *88)
EEE = 3-digit event code: 911 (alarm), 101 (open), 102 (close),
811 (trouble)
00 = always displayed
NN = 2-digit user number or zone number, depending on the
type of event (EEE) that ocurred. NN=00 indicates AC
loss, sytem lowbattery or low battery in 5827.
TO CENTRAL STA. PHONE No.
10 = All except Open/Close
11 = All reports
12 = All reports
13 = All except Open/Close
TO END USER PHONE No.
Alarms, Open/Close
‡
, Troubles
Alarms, Troubles
Alarms, Open/Close
‡
, Troubles
Open/Close
‡
‡
Will report users 0, 5-8 or wireless
arm/disarm button zones 26-33; all other
zones and users do not report
✱
50
15 SEC DIALER DELAY (BURG)
†
[1]
0 = no; 1 = yes; UL installations = 0
✱
51
PERIODIC TEST REPORT
†
[3]
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days
(enter Test Code in field
*
64)
✱
52
FIRST TEST REPORT OFFSET
†
[3]
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours
(Time to 1st report from power up/programming or downloading).
✱
53
SESCOA/RADIONICS SELECT
[0]
0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only reporting).
Select 0 for all other formats.
✱
54
LACK OF USAGE NOTIFICATION
[0]
0 = Disabled 4 = 90 days
1 = 1 day 5 = 180 days
2 = 7 days 6 = 365 days
3 = 27 days
✱
56
ENHANCED ZONE PROGRAMMING See procedure in this guide and refer to the Installation Guide.
✱
58
RF JAM DETECT
[0]
0 = no RF Jam Detection; 1 = RF Jam Detect on, no CS report;
2 = RF Jam Detect on with CS report
(if trouble/restore report is enabled in fields *60, *71)
Notes: (1)
This feature cannot be used in conjunction with the 5827 wireless
keypad.
(2)
For event logging option 2 must be selected.
†
Entering a number other than the one specified may give unpredictable results.