- 5 -
Field Function
Programmed Values [ ] = Table 1 Default Value
✱
42
SECONDARY PHONE NUMBER
Enter up to 24 digits; Do not fill unused spaces. If fewer than 24 digits
entered, pressing
*
advances to the next field. To clear entries from
field, press
*
42
*
.
For fields *43 , *44:
Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter
✱
as 4th digit, if 3+1 dialer reporting is to be
used. If only 3 digits used, pressing
✱
advances to the next field.
To clear entries from field, press
✱
43
✱
or
✱
44
✱
.Examples:
For Acct.
1234
, enter: 1 | 2 | 3 | 4
; For Acct.
B234
, enter: #+11| 2 | 3 | 4
For Acct.
123
, enter: 1 | 2 | 3 |
✱
✱
43
PRIMARY SUBS ACCT #
[15, 15, 15, 15]
✱
44
SECONDARY SUBS ACCT #
See note on previous page
✱
47
PHONE SYSTEM SELECT
†
[1]
(LYNXR/LYNXR24)
†
[5]
(LYNXR-EN)
For LYNXR/LYNXR24 only options 0, 1, 2, and 3 are applicable
Central
Dialing Mode
Station Pulse Tone Pulse Tone
No WATS
0 = No Speaker
Phone
1 = No Speaker
Phone
4 = With
Speaker Phone
5 = With
Speaker Phone
WATS
2 = No Speaker
Phone
3 = No Speaker
Phone
6 = With
Speaker Phone
7 = With
Speaker Phone
✱
48
REPORT FORMAT for PRIM./SEC
[7, 0]
Primary Secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
†
Entering a number other than the one specified may give unpredictable results.
Note:
If you are using Pulse
(rotary) Dialing, make sure
that LYNX has finished
dialing the last number you
dialed (listen to pulses)
Note:
Option 7 (ADEMCO Contact ID®) must