ADEMCO Vista-128B PLUS Especificações

Consulte online ou descarregue Especificações para Sistemas de segurança - controlo de acesso ADEMCO Vista-128B PLUS. ADEMCO Vista-128B PLUS Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 128
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
K5894 2/02 Rev B
9
9
,
,
6
6
7
7
$
$
%
%
3
3
9
9
,
,
6
6
7
7
$
$
%
%
3
3
&RPPHUFLDO%XUJODU\
3DUWLWLRQHG6HFXULW\6\VWHP
ZLWK6FKHGXOLQJ
,QVWDOODWLRQDQG6HWXS*XLGH
ON
OFF
1
OFF
4
MAX
7
INSTANT
READY
2
AW
AY
5
TEST
8
CO
DE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
®
.
Vista de página 0
1 2 3 4 5 6 ... 127 128

Resumo do Conteúdo

Página 1 - &RPPHUFLDO%XUJODU\

K5894 2/02 Rev B 99,,6677$$%%3399,,6677$$%%33&RPPHUFLDO%XUJODU\3DUWLWLRQHG6HFXULW\6\VWHPZLWK6FKHGXOLQJ ,QVWDOODWL

Página 2

VISTA-128BP/VISTA-250BP Installation and Setup Guide 1-4 Additional Features • Provides up to 60 installer-defined, custom words that can be used for

Página 3 - Table of Contents

VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-2 Level 6: Duress Codes • Sends a silent alarm to a central monitoring station if the user is b

Página 4

Section 9 – User Access Codes 9-3 Adding a Master, Manager, or Operator Code During user code entry, normal key depressions at other keypads in a par

Página 5 - List of Figures

VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-4 PROMPT EXPLANATION XMT USER DATA 1 = YES 0 = NO If the user number is from 001-050 this

Página 6

10-1 SECTION 10 Testing the System ••••••••••••••••••••••••••••••••••••••••••••••••• Battery Test When AC power is present, the VISTA-128BP/VISTA-25

Página 7 - General Description

VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-2 Step Action 5 Check that entry/exit delay zones provide the assigned delay times. 6 Check

Página 8

Section 10 – Testing The System 10-3 Trouble Conditions Check or Trouble Messages Display Description CHECK or TRBL (as per field 1✳07) This indicate

Página 9

VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-4 Contacting Technical Support PLEASE, before you call Technical Support, be sure you: • READ

Página 10

A-1 APPENDIX A Regulatory Agency Statements ••••••••••••••••••••••••••••••••••••••••••••••••• UL Installation Requirements The following requirement

Página 11 - Common Lobby Logic

VISTA-128BP/VISTA-250BP Installation and Setup Guide A-2 UL611/UL1610 Central Station Burglary Alarm Follow the instructions for UL609 Local installat

Página 12 - COMMON LOBBY

Appendix A – Regulatory Agency Statements A-3 FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENT NOTE: This equipment has been tested and found

Página 13

2-1 SECTION 2 Partitioning and Panel Linking •••••••••••••••••••••••••••••••••••••••••••••••••• Theory of Partitioning This system provides the abil

Página 14 - Panel Linking

VISTA-128BP/VISTA-250BP Installation and Setup Guide A-4 CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-003

Página 15 - How to Use Panel Linking

B-1 APPENDIX B Summary of System Commands •••••••••••••••••••••••••••••••••••••••••••••••••• User Code Commands Add A User Code = User Code + 8 + Ne

Página 16

VISTA-128BP/VISTA-250BP Installation and Setup Guide B-2 Scheduling Commands Installer-Programmed Schedule Events = Installer Code + [#] + 80 (Install

Página 17 - Multi-Panel View Mode

C-1 APPENDIX C Specifications •••••••••••••••••••••••••••••••••••••••••••••••••• VISTA-128BP/VISTA-250BP CONTROL Physical: 14-1/2"W X 18"

Página 18

VISTA-128BP/VISTA-250BP Installation and Setup Guide C-2

Página 19 - Installing the Control

D-1 APPENDIX D Contact ID and Pager Event Codes •••••••••••••••••••••••••••••••••••••••••••••••••• TABLE OF CONTACT ID EVENT CODES Code Definition

Página 20 - Notes:

VISTA-128BP/VISTA-250BP Installation and Setup Guide D-2 Event Log and Pager Alpha Descriptors Alpha Event Description FIRE Fire Alarm DURESS Duress A

Página 21 - Figure 3-5

Appendix D – Contact ID and Pager Event Codes D-3 Alpha Event Description ARMED-AUTO Auto-Armed PARTIAL ARM Partial Armed ARMED-EARLY Armed Early ARM

Página 22 - Installing External Sounders

VISTA-128BP/VISTA-250BP Installation and Setup Guide D-4

Página 23 - Telephone Line Connections

Index-1 Index •••••••••••••••••••••••••••••••••••••••••••••••••• #93 Menu Mode Programming...4-2 #93 Menu Mode Prog

Página 24 - DETECTOR

VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-2 1*18 Affects Lobby (must be programmed by partition) Setting this field to 1 for a specific p

Página 25 - Figure 3-11

Index Index-2 CIRCUIT PROTECTORS ... C-1 Code + TEST [5]...

Página 26 - Tamper Supervision

Index Index-3 H Hardwire and Optional Expansion Zones...1-1 Hardwired (HW) Type 01...4-7

Página 27 - Installing RPM Devices

Index Index-4 Pager 5 Format ...5-16 Pager 5 ID Number ...

Página 28 - Wireless Zone Expansion

Index Index-5 Supervised RF...3-13 Supervised RF (RF) Type 03 ...

Página 29 - Menu Mode

E-1 APPENDIX E •••••••••••••••••••••••••••••••••••••••••••••••••• WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced wir

Página 30

E-2 ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates (&

Página 31

E-3 VISTA-128BP Summary of Connections Diagram ASSEMBLEDIN MEXICO++-N.C.N.C.N.O.2k EOLR(note 1)2k EOLR(note 1)+-+-+-BELLSIRENNO CONNECTIONTRANSFORMER

Página 32 - Installing Output Devices

E-4 VISTA-250BP Summary of Connections Diagram ASSEMBLEDIN MEXICO++-N.C.N.C.N.O.2k EOLR(note 1)2k EOLR(note 1)+-+-+-BELLSIRENNO CONNECTIONTRANSFORMER

Página 33 - Programming

¬.4lK5894 2/02 Rev B 165 Eileen Way, Syosset, New York 11791 Copyright © 2002 PITTWAY CORPORATION

Página 34 - J7 CONNECTOR

Section 2 – Partitioning and Panel Linking 2-3 Sequence #2: Office 1 Office 2 Lobby Action User #2: (Armed) Disarms Disarms User #1: Disarms (Disar

Página 35 - Remote Keypad Sounder

VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-4 The following is a typical display: S Y S T E M 1 2 3 4 5 6 7 8 S T A T U S R R N N A ✴

Página 36 - #93 Menu Mode

Section 2 – Partitioning and Panel Linking 2-5 • Users 001-050 are the only users that can perform panel linking and are automatically assigned pane

Página 37 - ECP RADIO

VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-6 Multi-Partition Multi-Panel Mode To perform a function in the Multi-Partition, Multi Panel mo

Página 38

Section 2 – Partitioning and Panel Linking 2-7 Multi-Panel View Mode To perform a function in the Multi-Panel View mode, follow the steps below: Step

Página 39 - CONTROL PANEL

VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-8

Página 40 - Setup Guide

3-1 SECTION 3 Installing the Control ••••••••••••••••••••••••••••••••••••••••••••••••• This section describes the procedures for mounting and wiring

Página 42

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-2 PCBOARD(Shows typical local Grade A listing installation)RUN BELL WIRESIN CONDUITPLUG THISKNO

Página 43 - Figure 3-37

Section 3 - Installing the Control 3-3 Installing the Keypads • Up to 31 addressable keypads (addresses 00-30) may be used (you may need to use an aux

Página 44 - 4 3 2 1

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-4 Installing External Sounders The VISTA-128BP/VISTA-250BP provides a bell circuit output for o

Página 45 - 8 ohm Speaker

Section 3 - Installing the Control 3-5 PANEL BELLPANEL BELLTOOTHERDEVICESNONPOLARIZED BURGLARYINDICATING DEVICESPOLARIZED FIREINDICATING DEVICEPOLARIZ

Página 46 - Connecting the Transformer

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-6 Wiring Burglary and Panic Devices to Zones 1-9 The maximum zone resistance is 100 ohms for z

Página 47

Section 3 - Installing the Control 3-7 Wiring 4-Wire Smoke Detectors UL Power to 4-wire smoke detectors must be supervised with an EOL device (use a

Página 48

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-8 Using 2-Wire Latching Glassbreaks on Zone 8 Zone 8 can support 2-wire glassbreak detectors.

Página 49

Section 3 - Installing the Control 3-9 Installing RPM Devices The polling loop provides both power and data to the RPM devices, and is constantly moni

Página 50

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-10 POLLING LOOP RATING:128mA MAXIMUM4192SDSMOKE4190RPM4278PIR232122+-POLLING LOOP2524TO RIGHT L

Página 51

Section 3 - Installing the Control 3-11 UL A response type (05 Day/Night) must be programmed for zones 990 (1st receiver) and 988 (2nd receiver) for U

Página 52 - #93 Menu Mode Programming

iii Table of Contents •••••••••••••••••••••••••••••••••••••••••••••••••• List of Figures...

Página 53

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-12 TO CONTROL'S REMOTE KEYPADCONNECTION POINTS. USE MAX. of 220 ft. [67m of #22 (0.64mm)WI

Página 54 - Zone Number Designations

Section 3 - Installing the Control 3-13 Transmitter Input Types All transmitters have one or more unique factory-assigned input (loop) codes. Transmi

Página 55 - Communication Defaults

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-14 Installing Output Devices The VISTA-128BP/VISTA-250BP support up to 96 outputs. Each device

Página 56

Section 3 - Installing the Control 3-15 00000ECP BusDip SwitchOptional Keyswitch ConnectionSIDEVIEWAll Switches shownin Up position.(ECP Address 23)T

Página 57 - SECTION 3

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-16 You cannot use Output 1 for the Ground Start if you are using it for a Smoke Detector Rese

Página 58

Section 3 - Installing the Control 3-17 Smoke Detector Reset Output 1 may be used to reset 4-wire smoke detectors. Use this output to trigger a low cu

Página 59

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-18 RS-485 Bus Wire Run Limitations The RS-485 bus from the first Panel Linking Module to the la

Página 60 - SECTION 9: User Access Codes

Section 3 - Installing the Control 3-19 Long Range Radio Connected to the ECP The control can support an ECP Long Range Radio (LRR) (7820, 7835C, and

Página 61 - Programming Guide

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-20 Trouble Messages The following messages are displayed on the 6139/6160 when a problem exists

Página 62

Section 3 - Installing the Control 3-21 Alphanumeric PP Date Time EA ZZZ SSSS AD Where: PP Partition number (e.g., P1) Date Date the event occurred

Página 63

Table of Contents iv SECTION 5: Data Field Descriptions ...

Página 64

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-22 Access Control Using VistaKey The VistaKey is a single-door access control module that, when

Página 65

Section 3 - Installing the Control 3-23 +WEEKLY TESTING IS REQUIREDTO ENSURE PROPER OPERATIONOF THIS SYSTEM.POLE Door Strike/Mag CoilDATA 1 (WHITE)

Página 66

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-24 Using the 4100SM To connect a serial printer using the 4100SM, refer to Figure 3-33and perfo

Página 67

Section 3 - Installing the Control 3-25 Step Action 3 Make 12V (+) and (–) and data-in and data-out connections from the VIP Module to the control, u

Página 68

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-26 If the phone plug is disconnected from the control, the premise’s phones will not operate.

Página 69

Section 3 - Installing the Control 3-27 Wiring Connections Before making connections, power down the control panel. To wire the TeleSmart, perform

Página 70

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-28 REAL-TIME CLOCK (RTC)123456789101112131415161718EARTHGROUNDTYPICALCONTROL'SAC TERMINALS

Página 71

Section 3 - Installing the Control 3-29 Panel Earth Ground Connections In order for the lightning transient protective devices in this product to be e

Página 72

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-30 3. In Table 3, enter devices connected to the Alarm Output. Calculate alarm currents, then

Página 73

Section 3 - Installing the Control 3-31 6. Use the Battery Selection Table to select the appropriate battery for the installation. Table 6: Battery S

Página 74

v List of Figures •••••••••••••••••••••••••••••••••••••••••••••••••• Figure 3-1: Installing the Lock ...

Página 75

VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-32

Página 76

4-1 SECTION 4 Programming ••••••••••••••••••••••••••••••••••••••••••••••••• NOTE: All references in this manual for number of zones, number of user

Página 77

VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-2 Entry Errors • If an address is improperly entered, the keypad displays “FC.” • If a program

Página 78

Section 4 – Programming 4-3 Below is a list of the main menus. For details refer to the VISTA-128BP/VISTA-250BP Programming Guide. MAIN MENU OPTIONS

Página 79 - Scheduling Options

VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-4 MAIN MENU OPTIONS SCHEDULED CHK-IN 1 = YES 0 = NO 0 For defining the schedule for the sys

Página 80 - Time Window Definitions

Section 4 – Programming 4-5 Communication Defaults *45 PRIMARY FORMAT [1] ADEMCO Contact ID *46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed *47

Página 81

VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-6 Communication Defaults for Zones (continued) ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd ZON

Página 82 - Holiday Schedule Programming

Section 4 – Programming 4-7 Type 07: 24-Hour Audible Alarm Sends a report to the central station and provides an alarm sound at the keypad and an audi

Página 83 - Time Windows

VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-8 Type 03 Supervised RF (RF) Select for 5800 Series RF transmitters that will be supervised for

Página 84 - Holiday Schedules

Section 4 – Programming 4-9 Programming for the Alpha Pager Module Programming for TeleSmart • In field 2*30, enter 1 to enable the Alpha Pager Modul

Página 85 - Time-Driven Events

vi Conventions Used in This Manual •••••••••••••••••••••••••••••••••••••••••••••••••• Before you begin using this manual, it is important that you

Página 86

VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-10 Using an RF Transmitter Zone A button type RF transmitter (5804) can be used to provide acce

Página 87

5-1 SECTION 5 Data Field Descriptions ••••••••••••••••••••••••••••••••••••••••••••••••• About Data Field Programming The following pages list this c

Página 88

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-2 FIELD TITLE and DATA ENTRIES EXPLANATION *10 Exit Delay #1 (partition-specific) Enter 03-1

Página 89

Section 5 – Data Field Descriptions 5-3 FIELD TITLE and DATA ENTRIES EXPLANATION *22 Keypad Panic Enables (partition-specific) 0 = disable 1 = enab

Página 90 - Temporary Schedules

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-4 FIELD TITLE and DATA ENTRIES EXPLANATION *32 Primary Subscriber’s Account Number (partitio

Página 91 - to enter this mode

Section 5 – Data Field Descriptions 5-5 FIELD TITLE and DATA ENTRIES EXPLANATION *42 Dial Tone Pause Enter the wait time for dial tone detection: 0

Página 92 - User Scheduling Menu Mode

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-6 FIELD TITLE and DATA ENTRIES EXPLANATION *52 Standard/Expanded Reporting Primary 0 = disab

Página 93 - Downloading Primer

Section 5 – Data Field Descriptions 5-7 FIELD TITLE and DATA ENTRIES EXPLANATION *85 Enable Dialer Reports for Panics & Duress (partition-speci

Página 94

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-8 FIELD TITLE and DATA ENTRIES EXPLANATION Exit Error Logic Enable 0 = disable 1 = enable Ex

Página 95 - On-Line Control Functions

Section 5 – Data Field Descriptions 5-9 • If a relay is programmed to activate on either an alarm or trouble, both zones must trip before the relay wi

Página 96 - Telco Handoff

1-1 SECTION 1 General Description •••••••••••••••••••••••••••••••••••••••••••••••••• About the VISTA-128BP/VISTA-250BP The VISTA-128BP/VISTA-250BP i

Página 97 - Setting the Real-Time Clock

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-10 FIELD TITLE and DATA ENTRIES EXPLANATION 1*33 TouchTone with Rotary Backup 0 = disable 1

Página 98

Section 5 – Data Field Descriptions 5-11 FIELD TITLE and DATA ENTRIES EXPLANATION 1*49 Suppress Transmitter Supervision Sound 0 = disable 1 = enabl

Página 99 - User Access Codes

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-12 FIELD TITLE and DATA ENTRIES EXPLANATION 1*74 Relay Timeout XXX Minutes Enter 000-127 tim

Página 100 - Multiple Partition Access

Section 5 – Data Field Descriptions 5-13 FIELD TITLE and DATA ENTRIES EXPLANATION 2*09 Open/Close Reports by Exception (partition-specific) 0 = dis

Página 101

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-14 FIELD TITLE and DATA ENTRIES EXPLANATION 2*30 Pager Installed 0 = disable 1 = enable Enab

Página 102 - Exiting the User Edit Mode

Section 5 – Data Field Descriptions 5-15 FIELD TITLE and DATA ENTRIES EXPLANATION 2*45 Pager 2 Partition Enable 0 = disable 1 = enable This field h

Página 103 - Testing the System

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-16 FIELD TITLE and DATA ENTRIES EXPLANATION 2*60 Pager 4 Trigger Event Enables 0 = disable 1

Página 104 - Go/No Go Test Mode

Section 5 – Data Field Descriptions 5-17 FIELD TITLE and DATA ENTRIES EXPLANATION 2*75 Pager 7 Phone Number Enter 0-9; #11 for *, #12 for #, #13 fo

Página 105 - To the Installer

VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-18

Página 106 - Contacting Technical Support

6-1 SECTION 6 Scheduling Options •••••••••••••••••••••••••••••••••••••••••••••••••• UL • You must program Bypass and Auto-Arm Fail reports for UL i

Página 107 - Regulatory Agency Statements

VISTA-128BP/VISTA-250BP Installation and Setup Guide 1-2 • Supports up to 50 2-wire latching glassbreak detectors on zone 8. • Supports up to 241 addi

Página 108 - Requirements

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Exception Reports This option allows the reporting of openings and closings to the central st

Página 109

Section 6 – Scheduling Options 6-3 Open/Close Schedules Definitions General The open/close scheduling is controlled by one of three schedules. Each s

Página 110

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-4 Scheduling Menu Mode The #80 Scheduling Menu Mode is used to program most of the scheduling a

Página 111 - Summary of System Commands

Section 6 – Scheduling Options 6-5 PROMPT EXPLANATION Timed Events ? 1 = YES 0 = NO 0 Enter 1 to program timed events for relay outputs, additi

Página 112

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-6 Daily Open/Close Schedules Each partition can be assigned one daily open/close schedule, plus

Página 113 - Specifications

Section 6 – Scheduling Options 6-7 Holiday Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide.

Página 114

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-8 1. Enter the schedule number (01-20) and time window number (01-20), and note the day of the

Página 115 - APPENDIX D

Section 6 – Scheduling Options 6-9 3. Enter the desired activation time (when the action is to take place). Select from: Activation Time Description

Página 116

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-10 ACTION CODES EXPLANATION ACTION SPECIFIER 06=Relay Group On 07=Relay Group Off 08=Rela

Página 117

Section 6 – Scheduling Options 6-11 ACTION CODES EXPLANATION ACTION SPECIFIER 67=Access Point Partition Grant 68=Access Point Partition Grant w/Ove

Página 118

Section 1 - General Description 1-3 Scheduling • Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights). •

Página 119

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-12 Limitation of Access Schedule Worksheet Enter the appropriate time window numbers for each a

Página 120

Section 6 – Scheduling Options 6-13 Temporary Schedule Worksheet Partition/Windows Mon Tue Wed Thu Fri Sat Sun 1 Disarm Window Start Time HH:

Página 121

VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-14 User Scheduling Menu Mode The system provides up to 20 “timers” available to the end user to

Página 122

7-1 SECTION 7 Downloading Primer (Remote Downloading is not a UL Listed feature) ••••••••••••••••••••••••••••••••••••••••••••••••• General Informati

Página 123

VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-2 The following items must be programmed for unattended download: • The account number (field ✳

Página 124 - APPENDIX E

Section 7 – Downloading 7-3 Getting On-Line with a Control Panel At the protected premises, the control panel must be connected to the existing teleph

Página 125

VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-4 Scheduled Download The VISTA-128BP/VISTA-250BP can be programmed to periodically and automati

Página 126 - SUMMARY OF CONNECTIONS

8-1 SECTION 8 Setting the Real-Time Clock ••••••••••••••••••••••••••••••••••••••••••••••••• General Information This system provides a real-time clo

Página 127 - VISTA-250BP

VISTA-128BP/VISTA-250BP Installation and Setup Guide 8-2

Página 128 - ¬.4l

9-1 SECTION 9 User Access Codes ••••••••••••••••••••••••••••••••••••••••••••••••• General Information The VISTA-128BP allows a total of 150 security