ADEMCO VISTA-250FBP Guia de Configuração

Consulte online ou descarregue Guia de Configuração para Sistemas de segurança - controlo de acesso ADEMCO VISTA-250FBP. ADEMCO VISTA-250FBP Setup guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 136
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
V
VV
V
V
VV
V
I
II
I
I
II
I
S
SS
S
S
SS
S
T
TT
T
T
TT
T
A
AA
A
A
AA
A
-
--
-
-
--
-
1
11
1
1
11
1
2
22
2
2
22
2
8
88
8
8
88
8
F
FF
F
F
FF
F
B
BB
B
B
BB
B
P
PP
P
P
PP
P
V
VV
V
V
VV
V
I
II
I
I
II
I
S
SS
S
S
SS
S
T
TT
T
T
TT
T
A
AA
A
A
AA
A
-
--
-
-
--
-
2
22
2
2
22
2
5
55
5
5
55
5
0
00
0
0
00
0
F
FF
F
F
FF
F
B
BB
B
B
BB
B
P
PP
P
P
PP
P
Commercial Fire and Burglary
Commercial Fire and BurglaryCommercial Fire and Burglary
Commercial Fire and Burglary
Partitioned Security System with Scheduling
Partitioned Security System with SchedulingPartitioned Security System with Scheduling
Partitioned Security System with Scheduling
Installation and Setup Guide
K0376V2 7/09 Rev. B
Vista de página 0
1 2 3 4 5 6 ... 135 136

Resumo do Conteúdo

Página 1 - K0376V2 7/09 Rev. B

VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------111111112222222288888888FFFFFFFFBBBBBBBBPPPPPPPP VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAA

Página 2

x Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 ✱27 TEST REPORT INTERVAL Y Enter 0001-9999 for th

Página 3 - Table of Contents

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 8-2

Página 4

9-1 SECTION 9 User Access Codes ••••••••••••••••••••••••••••••••••••••••••••••••• General Information The VISTA-128FBP system allows a total of 150

Página 5

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 9-2 Level 6: Duress Codes • Sends a silent alarm to a central monitoring station if the user i

Página 6 - List of Figures

Section 9 – User Access Codes 9-3 Adding a Master, Manager, or Operator Code During user code entry, normal key depressions at other keypads in a par

Página 7 - PRODUCT MODEL NUMBERS:

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 9-4 PROMPT EXPLANATION XMT USER DATA 1 = YES 0 = NO If the user number is from 001-050 th

Página 8

10-1 SECTION 10 Testing the System ••••••••••••••••••••••••••••••••••••••••••••••••• Battery Test When AC power is present, the VISTA-128FBP/VISTA-2

Página 9 - General Requirements

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 10-2 PROMPT EXPLANATION AUTO-TEST DET? 0=NO 1=YES Enter 1 (YES) to have the system automati

Página 10

Section 10 – Testing the System 10-3 The system automatically exits the Test mode if there is no activity (no doors or windows are opened and closed,

Página 11

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 10-4 Trouble Conditions Supervisory Messages Display Description SUPV + Zone Number This indic

Página 12 - COMMUNICATIONS

Section 10 – Testing The System 10-5 To the Installer Regular maintenance and inspection (at least annually) by the installer and frequent testing by

Página 13

xi Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 1✱30 RF RECEIVER SUPERVISION CHECK-IN INTERVAL N

Página 14

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 10-6

Página 15 - General Description

A-1 APPENDIX A Regulatory Agency Statements ••••••••••••••••••••••••••••••••••••••••••••••••• UL Installation Requirements UL This system may be use

Página 16

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide A-2 UL609 Local Mercantile Premises/Local Mercantile Safe & Vault 1. All zones must be con

Página 17

Appendix A – Regulatory Agency Statements A-3 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENTS The user shall not make any changes or modifications

Página 18 - GREEN DATA

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide A-4 CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-00

Página 19 - Partitioning

B-1 APPENDIX B Summary of System Commands •••••••••••••••••••••••••••••••••••••••••••••••••• User Code Commands Add A User Code = User Code + 8 + Ne

Página 20 - COMMON LOBBY

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide B-2 Relay Control Commands Activate Relay for Current Partition = User Code + 0.

Página 21

C-1 APPENDIX C Specifications •••••••••••••••••••••••••••••••••••••••••••••••••• VISTA-128FBP/VISTA-250FBP CONTROL Physical: 18"H X 14-1/2&quo

Página 22

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide C-2

Página 23 - Installing the Control

D-1 APPENDIX D Contact ID Codes •••••••••••••••••••••••••••••••••••••••••••••••••• TABLE OF CONTACT ID EVENT CODES Code Definition 110 Fire Alarm 1

Página 24 - Commercial Fire Guidelines

xii Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 2✱21 SUPERVISION PULSES FOR COMMUNICATIONS DEV

Página 25 - Installing the Keypads

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide D-2 Code Definition 604 Fire Test 606 Listen-In to Follow 607 Burglary Walk-Test 608 Off-Norma

Página 26 - #93 Menu

Appendix D – Contact ID Codes D-3 Alpha Event Description RFLB RST RF Low Battery Restore EXP RST Expansion Module Failure Restore TMPR RST Tamper

Página 27

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide D-4

Página 28

Index-1 Index •••••••••••••••••••••••••••••••••••••••••••••••••• # #93 Menu Mode Programming ...4-2 #93 Menu Mode Programming

Página 29

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide Index-2 Bypass Commands ...6-8 C California State Fir

Página 30 - Auxiliary Relay Connections

Index Index-3 First Communication ...7-3 First Test Report Time ...5-7 For

Página 31 - Main Dialer Connections

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide Index-4 P PABX Access Code...5-3 Panic Button or Spee

Página 32

Index Index-5 Temporary Schedules Programming ...6-13 Test Report Interval...5-3 Testing The Syst

Página 34 - 2000 OHMS

THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced wireless security system, it does not offer guaranteed protection against bur

Página 35 - Figure 3-11

xiii Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 3✱60 BELL 2 & AUX RELAY TIMEOUT Y Enter 0

Página 36

For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa

Página 41 - #93 Menu Mode

V250FBP-SOC-V5VISTA-128FBP / VISTA-250FBPSUMMARY OF CONNECTIONSTRANSFORMERW/ENCLOSUREADEMCO No.1451(supplied)INPUT: 120VAC, 60HZ,

Página 42 - 5881-001-V0

ÊK0376V2ŠÊK0376V2ŠÊK0376V2ŠÊK0376V2Š K0376V2 7/09 Rev. B 2 Corporate Center Drive, Suite 100P.O. Box 9040, Melville, NY 11747

Página 44

1-1 SECTION 1 General Description ••••••••••••••••••••••••••••••••••••••••••••••••• SIA Installations The VISTA-128FBP and VISTA-250FBP are not cert

Página 45

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 1-2 Arming/Disarming and Bypassing • Can arm the system with zones faulted (Vent Zone). These

Página 46 - SWITCH (N.O.)

Section 1 - General Description 1-3 • Can periodically and automatically perform a scheduled download. • Revision 4.0 and above panels can be downlo

Página 47

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 1-4 BLACK -RED +YELLOW DATAGREEN DATABLACK -RED +YELLOW DATAGREEN DATABLACK -RED +YELLOW DATAGR

Página 48 - Connecting the Transformer

2-1 SECTION 2 Partitioning ••••••••••••••••••••••••••••••••••••••••••••••••• Theory of Partitioning This system provides the ability to arm and disa

Página 50

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 2-2 The Common Lobby feature employs logic for automatic arming and disarming of the common lob

Página 51

Section 2 – Partitioning 2-3 Sequence #2: Office 1 Office 2 Lobby Action User #2: (Armed) Disarms Disarms User #1: Disarms (Disarmed) (No change) U

Página 52 - Battery

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 2-4 The following is a typical display: S Y S T E M 1 2 3 4 5 6 7 8 S T A T U S R R N N A

Página 53 - MAIN PCB

3-1 SECTION 3 Installing the Control ••••••••••••••••••••••••••••••••••••••••••••••••• This section describes the procedures for mounting and wiring

Página 54

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-2 RUN BELL WIRESIN CONDUITPLATECABINETMOUNTINGSCREWS(3)fire_burg_cab-001-V0PCBOARDRUN ALL REM

Página 55

Section 3 - Installing the Control 3-3 Installing the Control's Circuit Board To install the circuit board in the cabinet, perform the following

Página 56 - #93 Menu Mode Programming

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-4 REDKEYPADSBLACKGREENYELLOWCONTROLTERMINALS 12131411kypd_conn-001-V0 Figure 3-5: Keypad Con

Página 57 - OPTIONS

Section 3 - Installing the Control 3-5 If you purchased a kit containing the PS24 Power Supply Module, you may use this module to convert one or both

Página 58 - Zone Number Designations

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-6 ALARM INDICATING DEVICE TYPE MANUFACTURER MODEL # 4-Wire Wall Mount Horn/Strobe, 12/24V,

Página 59

Section 3 - Installing the Control 3-7 Table 3-1: BELL 1 AND BELL 2 MAXIMUM DEVICE RATING NOTE: To use this table, the device Candela Setting and Horn

Página 60

iii Table of Contents ••••••••••••••••••••••••••••••••••••••••••••••••• Commercial Fire and Burglary...

Página 61 - SECTION 3:

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-8 Supervising the Notification Appliance Circuits To wire the NAC using the supervision featu

Página 62 - Zone Input Type Definitions

Section 3 - Installing the Control 3-9 +--+-+•EOLPOWERSUPERVISIONRELAYMODULEEOLR-14-WIRE SMOKEDETECTORS2000OHMEOLRHEATDETECTOR+–BLK+-ZONE TERMINALS(15

Página 63 - Programming for Communicator

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-10 power is lost. Zone 974 (Primary Dialer Supervision) must be enabled in order for the

Página 64

Section 3 - Installing the Control 3-11 Dialer Operation When only the main dialer is enabled (field 3✳30 = 1,0), the system attempts to route all mes

Página 65 - Programming Guide

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-12 UL • These smoke detectors are UL Listed for use with the VISTA-128FBP/VISTA-250FBP

Página 66

Section 3 - Installing the Control 3-13 Wiring 4-Wire Smoke Detectors UL • Power to 4-wire smoke detectors must be supervised with an EOL device

Página 67 - Report Code Programming

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-14 GLASSBREAKDETECTORZONE 8 (+)(-)LATCHING TYPE GLASSBREAK DETECTOR LOOP2000OHMSEOLR 2726glas

Página 68

Section 3 - Installing the Control 3-15 2k EOLR+TAMPERSWITCHSENSOR Figure 3-14: Wiring a Normally Open Sensor Loop for Tamper Supervision Installing

Página 69

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-16 Compatible Polling Loop Devices Model Number Type 4297 Extender Module 4208SN 8 Zone V-P

Página 70

Section 3 - Installing the Control 3-17 272526+polling_loop-012-V22928VPLEX-VSITOBURG DEVICESTOFIRE DEVICESNOTE: FIRE DEVICES MAYBE WIRED DIRECTLY TOT

Página 71

Table of Contents iv Zone Response Type Definitions...

Página 72

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-18 INPUT POLLING LOOPCONTROL PANELEXTENSION POLLING LOOP #1 4297COMBINED INPUT AND EXTENSION

Página 73

Section 3 - Installing the Control 3-19 UL A response type 19 (24-Hour Trouble) must be programmed for zones 990 (1st receiver) and 988 (2nd receiver

Página 74

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-20 5881ENHC-001-V0SCREW Figure 3-18: Installing the 5881ENHC with Tamper Protection TO CONTRO

Página 75 - Output Programming

Section 3 - Installing the Control 3-21 Transmitter Input Types All transmitters have one or more unique factory-assigned input (loop) codes. Transmi

Página 76

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-22 Installing Output DevicesThe VISTA-128FBP/VISTA-250FBP supports up to 96 outputs. Each dev

Página 77

Section 3 - Installing the Control 3-23 4204CF ADDRESS SETTINGSSWITCHNUMBER("—" means "OFF")0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 152

Página 78 - ✳16 for Waterflow and

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-24 LED Indications Green Red Indication On Off Disarmed & Ready Off Off Disarmed &am

Página 79

Section 3 - Installing the Control 3-25 Communicators Connected to the ECP The control can support an IP or GSM communications device (7845i-ent, 7845

Página 80

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-26 Installing the Communicator To install the communications device, perform the following st

Página 81 - Scheduling Options

Section 3 - Installing the Control 3-27 The control panel kit you purchased comes with the appropriate transformer. Both transformers have a manually

Página 82 - Time Window Definitions

Table of Contents v UL Installation Requirements...

Página 83

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-28 Determining the Control’s Power Supply Load In the event of an AC power loss the VISTA-128

Página 84

Section 3 - Installing the Control 3-29 3. In Worksheet 3, enter devices used on Auxiliary Power 2. Calculate standby and alarm currents, then add to

Página 85 - #80 Scheduling Menu Mode

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-30 If you are using the PS24, skip the Battery Capacity Calculation Worksheet that follows an

Página 86 - Holiday Schedules

Section 3 - Installing the Control 3-31 BLACKREDBLACKRED12VBATTERY12VBATTERY(IF REQUIRED)++BATTERY TABSMAIN PCB DUAL BATTERYHARNESS(2 PAIRSSUPPLIED)OB

Página 87 - Time-Driven Events

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-32

Página 88

4-1 SECTION 4 Programming ••••••••••••••••••••••••••••••••••••••••••••••••• NOTE: All references in this manual for number of zones, number of user

Página 89

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-2 In either of the above cases, simply re-enter [✳] + the correct field number and then enter

Página 90 - 50=Off-Normal Reminder

Section 4 – Programming 4-3 Below are the main menu selections. For details refer to the VISTA-128FBP/VISTA-250FBP Programming Guide. MAIN MENU OPTION

Página 91 - 3…8

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-4 MAIN MENU OPTIONS SCHEDULED CHK-IN 1 = YES 0 = NO 0 For defining the schedule for the s

Página 92 - Temporary Schedules

Section 4 – Programming 4-5 Communication Defaults *45 PRIMARY FORMAT [1] ADEMCO Contact ID *46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed *47

Página 93

vi List of Figures ••••••••••••••••••••••••••••••••••••••••••••••••• Figure 1-1: Isolating Fire Devices from Burglary Devices...

Página 94 - User Scheduling Menu Mode

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-6 Communication Defaults for Zones (continued) ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1s

Página 95 - Downloading Primer

Section 4 – Programming 4-7 Type 09: Supervised Fire (Without Verification) Provides a fire alarm on a short circuit and a trouble condition on open c

Página 96

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-8 Zone Input Type Definitions Each zone must be assigned an input type, which defines the whe

Página 97 - Section 7 – Downloading

Section 4 – Programming 4-9 Using a Relay to Unlock a Door This control can be programmed so that a user can trigger a relay for 2 seconds (e.g., to u

Página 98 - Figure 7-1

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-10

Página 99 - Setting the Real-Time Clock

5-1 SECTION 5 Data Field Descriptions ••••••••••••••••••••••••••••••••••••••••••••••••• About Data Field Programming The following pages list this c

Página 100

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-2 FIELD TITLE and DATA ENTRIES EXPLANATION *10 Exit Delay #1 (partition-specific) Enter 03

Página 101 - User Access Codes

Section 5 – Data Field Descriptions 5-3 FIELD TITLE and DATA ENTRIES EXPLANATION *23 Multiple Alarms (partition-specific) 0 = disable 1 = enable I

Página 102 - Master Oper B

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-4 FIELD TITLE and DATA ENTRIES EXPLANATION *33 Primary Phone Number Enter 0-9; #11 for *,

Página 103 - EXPLANATION

Section 5 – Data Field Descriptions 5-5 FIELD TITLE and DATA ENTRIES EXPLANATION *44 Ring Detection Count Enter 00 to disable ring detection. Ent

Página 104 - Exiting the User Edit Mode

vii Conventions Used in This Manual ••••••••••••••••••••••••••••••••••••••••••••••••• Before you begin using this manual, it is important that you un

Página 105 - Testing the System

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-6 FIELD TITLE and DATA ENTRIES EXPLANATION *54 Unattended Mode 0 = disable 1 = enable If

Página 106 - Burglary Walk-Test (

Section 5 – Data Field Descriptions 5-7 FIELD TITLE and DATA ENTRIES EXPLANATION *83 First Test Report Time Enter 00-07the for day (01 = Monday) En

Página 107 - Armed Burglary System Test

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-8 FIELD TITLE and DATA ENTRIES EXPLANATION 1*13 System Sensor Reversing Relay 0 =use nei

Página 108 - Trouble Conditions

Section 5 – Data Field Descriptions 5-9 Conditions That Affect Cross-Zone Operation • In the event of a continuous fault (lasting at least 5 minutes)

Página 109 - To the Installer

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-10 FIELD TITLE and DATA ENTRIES EXPLANATION 1*33 TouchTone with Rotary Backup 0 = disable

Página 110

Section 5 – Data Field Descriptions 5-11 FIELD TITLE and DATA ENTRIES EXPLANATION 1*52 Send Cancel If Alarm + Off (partition-specific) 0 = disabl

Página 111 - Regulatory Agency Statements

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-12 FIELD TITLE and DATA ENTRIES EXPLANATION 1*76 Control Relay (partition-specific) 01-96

Página 112

Section 5 – Data Field Descriptions 5-13 FIELD TITLE and DATA ENTRIES EXPLANATION 2*09 Open/Close Reports by Exception (partition-specific) 0 = dis

Página 113 - FCC PART 68 NOTICE

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-14 FIELD TITLE and DATA ENTRIES EXPLANATION 3*00 Check or TRBL Display 0 = CHECK 1 = TRBL

Página 114

Section 5 – Data Field Descriptions 5-15 FIELD TITLE and DATA ENTRIES EXPLANATION 3*19 Auxiliary Input Alternate Function Enable 0 = disable 1 = en

Página 116

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-16 FIELD TITLE and DATA ENTRIES EXPLANATION 3*59 Enable Bell 2 & Auxiliary Relay Chim

Página 117 - Specifications

6-1 SECTION 6 Scheduling Options ••••••••••••••••••••••••••••••••••••••••••••••••• UL • You must program Bypass and Auto-Arm Fail reports for UL i

Página 118

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-2 Exception Reports This option allows the reporting of openings and closings to the central

Página 119 - Contact ID Codes

Section 6 – Scheduling Options 6-3 Open/Close Schedules Definitions General The open/close scheduling is controlled by one of three schedules. Each s

Página 120 - Event Log Alpha Descriptors

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-4 Scheduling Menu Mode The #80 Scheduling Menu Mode is used to program most of the scheduling

Página 121

Section 6 – Scheduling Options 6-5 PROMPT EXPLANATION Access Sched. ? 1 = YES 0 = NO 0 Enter 1 to program access schedules. Refer to Limitation

Página 122

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-6 Daily Open/Close Schedules Each partition can be assigned one daily open/close schedule, pl

Página 123

Section 6 – Scheduling Options 6-7 Holiday Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide.

Página 124 - 4-3, 4-4

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-8 1. Enter the schedule number (01-20) and time window number (01-20), and note the day of t

Página 125 - 6-4, 6-2

Section 6 – Scheduling Options 6-9 Field *04 must be enabled for randomization. A user must initiate a random schedule by entering one of the followin

Página 126

ix UL864 (Commercial Fire) Compliance ••••••••••••••••••••••••••••••••••••••••••••••••• General Requirements The VISTA-128FBP/VISTA250FBP control pan

Página 127 - 6-4, 6-5

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-10 ACTION CODES EXPLANATION ACTION SPECIFIER 30=Auto bypass – Zone list 31=Auto unbypass

Página 128

Section 6 – Scheduling Options 6-11 Limitation of Access Schedules Limitation of Access is a means by which a user’s access code is limited to workin

Página 129

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-12 Limitation of Access Schedules Programming To program access schedules enter Scheduling Me

Página 130

Section 6 – Scheduling Options 6-13 Temporary Schedule Worksheet Partition/Windows Mon Tue Wed Thu Fri Sat Sun 1 Disarm Window Start Tim

Página 131

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-14 User Scheduling Menu Mode The system provides up to 20 “timers” available to the end user

Página 132

7-1 SECTION 7 Downloading Primer (Remote Downloading is not a UL Listed feature) ••••••••••••••••••••••••••••••••••••••••••••••••• General Informati

Página 133

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 7-2 been selected at the station – otherwise Compass will disconnect). If Compass does not have

Página 134

Section 7 – Downloading 7-3 Getting On-Line with a Control Panel At the protected premises, the control panel must be connected to the existing teleph

Página 135 - WARNING:

VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 7-4 Scheduled Download (For Burglary Use Only) The VISTA-128FBP/VISTA-250FBP can be programmed

Página 136 - ÊK0376V2ŠÊK0376V2Š

8-1 SECTION 8 Setting the Real-Time Clock ••••••••••••••••••••••••••••••••••••••••••••••••• General Information This system provides a real-time clo

Comentários a estes Manuais

Sem comentários