ADEMCO VISTA-50PEN Instruções de Operação Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 84
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
18
Security Codes & Authority Levels (contd)
To Exit User Edit Mode
You can exit any of the user edit modes described on the following
pages at any time by doing the following:
1. Press either
or
#
, or don't press any key for 10 seconds.
2. System returns to normal mode.
To Add a User
IMPORTANT:
Temporary users should not be shown how to use any
system function they do not need to know (e.g. bypassing protection
zones).
CODE
1. Enter Master or Manager code and press the 8 key.
2. Enter the new user's 3-digit User Number (002-150).
3. Enter 4-digit security code for that user. The following prompts will
appear.
ADD NEW USER?
0 = NO , 1 = YES
Enter 1 to add a new user code. Entering 0
will change the existing user's code to the code
entered in step 3. See Changing A User's Code
section.
USER NUMBER = 003
ENTER AUTH. LEVEL
Enter the authority level, 1-6, for this user
within this partition.
1=master 2=manager 3=operator A
4=operator B 5=operator C 6=duress code
ACCESS GROUP?
ENTER 0-8
If access schedules have been programmed,
this prompt appears. Enter the user's access
group number (1-8) if this user should have
limited access to the system. Enter 0 if no
access group should be assigned.
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 83 84

Comentários a estes Manuais

Sem comentários