ADEMCO LYNX Manual do Utilizador Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
- 8 -
96
INITIALIZES DOWNLOAD ID, SUBSCRIBER ACCOUNT No. FOR INITIAL DOWNLOAD: No entry required.
97
SELECT 1 OF 4 DEFAULT OPTION SETUPS. Enter 1-4 to select from default tables 1-4. Enter 0 to abort.
98
EXITS PROGRAMMING MODE AND PREVENTS
RE-ENTRY by: Installer Code + 8+ 0 + 0.
If
98 is used to exit programming mode, you must press "
" and "#" within 50 seconds of power up or
from exiting Programming mode to re-enter Programming mode.
99
EXITS PROGRAMMING MODE AND ALLOWS
RE-ENTRY by: Installer Code + 8 + 0 + 0 or: Power-up,
then press "
" and "#" within 50 seconds of power up or from exiting Programming mode.
After exiting Program mode, the system takes up to 1 minute to reset. To bypass the reset delay, press [#] + [0].
*56 ENHANCED ZONE PROGRAMMING PROCEDURE
Use this mode to program zone information. Press *56 while in programming mode.
NOTE:
Entry of a number other than one specified will give unpredictable results.
%-
ZONE NUMBER
Enter the 2-digit zone number to be programmed:
Zone 1 =
hard wire zone
[*] = Continue
Zones 2-25 = RF transmitter zones
00 = exit zone programming mode;
Zone 26-41 = RF button zones
upon exiting, the prompt “56” blinks; press
Zone 92 = Duress
[*] + any field number to go to that field.
Zone 95, 96, 99 = Panic zones
b
zt
ZONE TYPE
Enter the 2-digit zone type (
zt
) for this zone (see table of zone types on worksheet page 13).
[*] = Continue [if 00 is entered the system will skip to DELETE ZONE PARAMETERS prompt (F)].
[#] = Return to previous prompt
'
rc
REPORT CODE
Enter the report code (
rc
) for this zone.
Report consists of 2 hexadecimal digits, each of which consist of 2 numerical digits (A = 10, B = 11, C =
12, D = 13, E = 14, F = 15; see Report Code description on page 6 for explanation of codes).
[*] = Continue; If this is zone 1, 95, 96 or 99, the system skips to the VOICE DESCRIPTOR prompt (1C)
[#] = Return to previous prompt
d
i
INPUT TYPE
Enter the input type (
i
) for the transmitter assigned to this zone as follows:
3 = Supervised RF (RF) [*] = Continue
4 = Unsupervised RF (UR) [#] = Return to previous prompt
5 = Button type (BR)
)
l
0
LOOP NUMBER
Enter the loop number (
l
) for this zone. If “L” is displayed, the serial number for this transmitter has
already been entered. You can keep the serial number and skip to the VOICE DESCRIPTOR prompt, or
you can continue to the DELETE SERIAL NUMBER prompt.
0 + [*] = to Delete Serial Number prompt (F)
[*] = Continue to the ENROLL MODE prompt (1A) if not enrolled, or VOICE DESCRIPTOR prompt (1C) if
already enrolled.
[#] = Return to previous prompt
1-4 = Loop number for the zone of the transmitter being entered
*
DELETE ZONE PARAMETERS
0 = Discard the delete request.
1 = Confirm the requested delete.
If 00 is entered in the zone type, confirmation of the delete request will delete all information associated
with zone currently being programmed.
If 0 is entered in the loop number, confirmation of the delete request will delete the serial number
associated with zone currently being programmed.
Note:
00 was entered as a zone type in prompt (b), 00 will be retained and system will advance to prompt (1C).
-% 0'
ENROLL MODE
0 = Skip to the VOICE DESCRIPTOR prompt (1C). If zone type is “00,” then skips to DELETE SERIAL
NUMBER prompt instead.
1 = Enroll now and proceed to SERIAL NUMBER prompt (1b).
2 = Copy the last serial number from the local memory buffer.
3 = View existing serial number. (Only if “L” is displayed).
9 = Delete existing serial number. (Only if “L” is displayed).
[*] = Advance to the VOICE DESCRIPTOR prompt (1C). This will save all zone parameters.
[#] = Return to the loop number prompt (E).
Note:
“L” will be displayed only if transmitter was already learned. “C” will be displayed only after
confirmation
.
Vista de página 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Comentários a estes Manuais