DATA LOAD MODE PROCEDURES
(See Diagram 5)
These procedures describe a means of programming (downloading) No. 533o
tinsoles from a master No. 533o Console (which has been programmed via its
keypad) and are useful for saving time and i“suting that each Console is
programmed identically when installing additional Consoles at a users
premises.
To display the vatious data load menus, press the [PgDn] key when ,’Data Load
Mode” is displayed. To return to “Normal Mode”, press [ShiiVPgUp] twice,
PROGRAMMING FROM A NO. 533o ALPHA CONSOLE
Follow these procedures when programming additional Consoles from a, No.
5330 Console which has already been programmed. A Download Adapter
Cable No. 533oAC is required. See connection diagram on SPECIFICATIONS
page.
1. Remove theprogrammed Console (source) from thewall and disconnect
its cable. Connect the No. 533oAC adapter cable to the removed cable
connector that is intefiaced with the control system, to the source
Console, and to the Console to be programmed (destination), as shown.
2. Atthesource Console, enter the'' installer's D.A. Mode'', press [PgDn],
then press [Next] until’’Data Load Mode’’ appears. Press[Pg Dn], lhen
press [Next] until’’Upload: Ext533~ appears. Press[Pg Dn] to display
“Ready to Upload.
3. Atthedestination Console, enter the “lnstalIer’sD.A. Mode’’, press[Pg
Dn], andpress [Next] until’’Data Load Mode’’ appears. Press[Pg Dn]
~Dnload: Ext 533V appears). Press [PgDn] again to display “Ready for
Dnload (frm 5330)/Pg Up”.
4. Besurethat thedestination Console display sthe''Ready for download''
message and that the source Console displays the “Readyfor Upload”
message. If not, check all connections and repeat steps2 and 3. When
both messages are displayed, press thesource Consolers [Shiit/Store]
key to begin programming. “Uploading to 5330” appears on the the source
Console, and “Downloading from 533o” appears on the destination
tinsole wtile programming is in progress.
5. When programming incomplete, the message’’Upload complete (to
5330~ appears on the source Console, and the message “Dnload
complete (from 533 O)"appears onthedestination Console and a beep
is heard. Return both Consoles to “Normal Mode” by repeatedly
pressing [ShifffPg Up] tithe message’’Dnload failure” appears on either
Console, check all connections and repeat the programming procedure.
6. Repeat the previous procedures for each additional Console being
installed. When all Consoles have been programmed, disconnect the
adapter cable, plug the intetiace cable back into the source Console’s
mnnector, and remount the source Console. ThedeSination Console(s)
may now be installed.