– 6 –
OUTPUT AND SYSTEM SETUP (
*
80–
*
93)
*
80 OUTPUT RELAYS AND POWERLINE CARRIER DEVICES
Program only if Relays and/or Powerline Carrier devices are to be used. See next page.
*
81 ZONE LISTS FOR OUTPUT DEVICES
Program only if Relays and/or Powerline Carrier devices are to be used. See next page.
*
82 CUSTOM ALPHA EDITING (Also entered from field
*
56):
See procedure in instructions.
*
90 EVENT LOGGING [3]
0 = None; 1 = Alarm/Alarm Restore; 2 = Trouble/Trouble
Restore; 4 = Bypass/Bypass Restore; 8 = Open/Close.
Example:
To select “Alarm/Alarm Restore”, and “Open/Close”,
enter 9 (1 + 8); To select all, enter #15.
Note: System messages are logged when any non-zero
selection is made.
*
91 OPTION SELECTION (AAV) [0]
0 = None; 4 = AAV; “0” for UL installations.
*
92 PHONE LINE MONITOR ENABLE [0]
0 = Not used
1 = Keypad display when line is faulted
2 = Keypad display plus keypad trouble sound
3 = Same as “2”, plus Device #2 STARTS. If either partition
is armed, external sounder activates also.
Note: Device #2 must either be programmed to be STOPPED in
field
*
80 or STOPPED by Code + # + 8 + 2.
*
93 No. OF REPORTS IN ARMED PERIOD [0]
0 = 10 Alarm/Alarm Restore Reports; 1 = Unlimited.
“1” for UL installations.
DOWNLOAD INFORMATION (
*
94,
*
95)
*
94 DOWNLOAD PHONE No. | | | | | | | | | | | | | | |
Enter up to 16 digits, 0–9; #+11 for '*'; #+12 for '#'; #+13 for a
pause. Do not fill unused spaces. If fewer than 16 digits entered,
exit field by pressing
*
(and press 95, if entering next field). To clear
entries from field, press
*
94
*
.
Note: In UL installations, down loading may only be performed if
a technician is at the site.
*
95 RING DET COUNT FOR DOWNLOADING [0]
0 = Disable Station Initiated Download; 1–14 = number of rings
(1–9, # +10 =10, # +11 =11, # +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15)
Note: Do not enter “0” if using 4285 Voice Module.
*
96 INITIALIZES DOWNLOAD ID, SUBSCRIBER ACCOUNT No. FOR INITIAL DOWNLOAD: No data entry.
*
97 SETS ALL PROGRAM FIELDS TO DEFAULT VALUES: No data entry.
*
98 and
*
99 USED TO EXIT PROGRAM MODE
*
98: Exits programming mode and
prevents
re-entry by:
Installer Code + 8+ 0 + 0. If
*
98 is used to exit programming
mode, system must be powered down, and method 1 above
used to enter the programming mode.
*
99: Exits programming mode and
allows
re-entry by: Installer
Code + 8 + 0 + 0 or: Power-up, then press "*" and "#" within 50
seconds of power up.
WWW.DIYALARMFORUM.COM