— 61 —
A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off; 4 =
Toggle alternately between START and STOP events
EV = EVENT 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble; 4 = Restore
ZL = ZONE LIST 01-15, 00 = Not Used
"START" ZONE LIST: Upon alarm, fault, trouble or restore of ANY zone in this list, device
action will START.
"STOP" ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It
need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00=zone not used 07=24-hour audible 21=arm away
01=entry/exit 1 08=24-hour auxiliary 22=disarm
02=entry/exit 2 09=supervised fire 23=no alarm response
03=perimeter 10=interior (delay) 26=VGM supervision
04=interior (follower) 14=PLM supervision 27=access control
05=day/night burglary 16=fire w/verification 28=MLB supervision
06=24 hour silent 20=arm stay 29=momentary exit
NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.
Any zone in "ZT" for Stop, that restores will stop the relay action.
Choices for System Operation are:
00 = No Response (Not Used) 42 = System Battery Low
01 = Entry/Exit #1 43 = Communication failure
02 = Entry/exit #2 44 = RF Low Battery
03 = Perimeter
27 = Access Point (allows more than
one relay to be controlled by
activation if access point
request)
45 = Polling Loop Failure
04 = Interior Follower 28 = MLB Supervision 47 = Console Failure
05 = Trouble Day/Alarm Night 29 = Momentary Exit 51 = RF Receiver Failure
06 = 24-Hr. Silent 31 = End of Exit Time 52 = Kissoff
07 = 24-Hr. Audible 32 = Start of Entry Time 54 = Fire Zone Reset
08 = 24-Hr. Auxiliary 33 = Any Burglary Alarm 55 = Disarm + 1 Minute
09 = Fire Alarm or Trouble 34 = Code + [#] + 71 Key Entry
10 = Interior W/Delay 35 = Code + [#] + 72 Key Entry
56 = XX Minutes (enter XX in field
1*74) *
16 = Fire With Verification 36 = At Bell Timeout **
20 = Arming-STAY*** 37 = 2 Times Bell Timeout **
57 = YY Seconds (enter YY in field
1*75) *
21 = Arming-AWAY**** 38 = Chime 58 = Duress
22 = Disarming (Code + Off) 39 = Fire Alarm
23 = No Alarm Response 40 = Bypassing
41 = AC Power Fail
60 = Audio Alarm Verification (must
be selected for both START and
STOP operation)
* Stop condition only
** Or at Disarming, whichever occurs earlier
*** The output also activates when the partition is armed in the INSTANT mode
**** The output also activates when the partition is armed in the MAXIMUM mode
P = PARTITION No. 1-8, 0 = Any
ZONE LISTS FOR OUTPUT DEVICES – Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the
required data on the worksheet below and follow the procedure shown earlier in this
Programming Guide
as you enter the
data during the displays and prompts that appear in sequence. Up to 15 zone lists may be created
Note:
Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include
any
or
all
of system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 000 to end entries).
Zone List 2: Started or stopped by zone numbers (enter 000 to end entries).