SA4120XMP-2 Trigger Cable with Pull-ups
(installer-provided) for use with LORRA.
Application
Programming & Wiring
SA4120XM-2 Trigger Cable for use with 4146
Keyswitch & Latching Glass Break Detectors.
An optional Amseco PAL 328N piezo sounder can be used for installations
where it is desired to remote the sounds produced by the console’s built-in
sounder. The control panel will remote all sounds (i.e., alarm, trouble, chime,
entry/exit, etc.) produced by the console except for the short key clicks
associated with console key depression.
One application of this feature might be to produce chime sounds in a location
which is distant from the console(s).
If used, Address 1*57 must be set to “2” or “3”, and the PAL 328N must be
connected to TB2 pin 5, as shown in the diagram below.
6
F
ls2
TRIGQER
HEADER
.!
TERMINM5
●
●
●
●
An optional remote 4146 keyswitch can be used for remote arming and
disarming of the system. If used, program field
●I 5 must be set to “1” to
enable the keyswitch option.
The
4146 keyswitch’s normally open momentary switch and LEDs must be
connected to Zone 7 and to the TB2 connector trigger outputs respectively.
A 2000 ohm EOL resistor must be connected across the momentaty switch,
and zones
2-8 must be programmed for EOLR supervision (0) in field 41.
Note:
In view of the above, all zones must be used with EOLR supervision
when a remote keyswitch is
used.
A momentary shori across this zone will arm the system in the “AWAY”
mode. If the short is held for more than 3 seconds, the system will arm in the
“STAY” mode. (i.e., all zones designated as zone types 4 or 10 will be
automatically bypassed). After the system has been armed, the next time
zone 7 is shorted, the system will disarm.