63 First Test Repofi
One 2digit fieid entry:
Time
Enter the time from the time that the programming mode is exited that the first
test report shall be transmitted, antior first battery test initiated. 00 entry signifies
immediately upon exiting. Default = 12 hours. See fields 81 & 82 for assigning
the Test Report code.
*64 Swinger
This option iimits the number of messages (Alarms or Troubles) sent for a
Suppression
specific channel in an armed period (Swinger Suppression) before additional
(00;01-15)
reports from that channel are inhibited. This seiection is system-wide.
NOTE: if zero is selected, all Aiarm or Trouble codes are reported. Must be “00”
(disabled) for UL. Default=15.
85-86 Not Used
*87 ENTRY WARNiNG
Enter O for 3 short beeps, or 1 for slow beeps that continue for the entire entry
H =cont10=3 beerx)
delay period.
*88 Burg. Aiarm Comm.
Enter Ofor no delay on burglary alarm communication, or 1
for 16-second
Deiay
delay (no delay on 24-hour
reports).
(Q/1)
89 Restore Report
Enter Ofor instant restore report, as zone restores. Enter 1 for reporting after bell
Timing
timeout if zone restored. Enter 2 for restore report
when system is subsequently
(Q/1/2)
disarmed
40 Secondary
Enter 3 or 4 numbers 00-09; B-F (11-15). Each number requires a 2-digit entry so
Subscriber Acct #
as to allow entry of hexadecimal digits (B-F). If a
3-digit number is to be used,
only enter data in the first 6 locations, leaving the last two unfilled.
Default=l 5 15 15 15. Use the chart in field
31 to determine the entry for each
digit. Erase the field by entering *90*. NOTE: This field
must be programmed if a
secondary phone number is used (field
34). This account number can be the
same as the rximaw account number.
1OO Open/Ciose Reporta
See Fields 39 and 4O for Users 1-16.
For Users 17-22 &
23-70
(1=yes; Q=no)
1O1 Response Type For (See
Field *05)
Zones 28-32
1O2 Response Type For (See Field 05)
Zones 33-40
1*O3 Response Type For
(See Field
05)
Zones 41-48
1*O4 Response Type For (See
Field 05)
Zones 49-56
1O5 Response Type For
(See
Field 05)
Zones 57-64
1*O8 Assign Response
Eight 2-digit field entries: The 2nd, 4th, 5th, 6th, and 7th must be 00.
Typas For Zones
81 (4219
supervision), 82 (not used), 83 (4219 Tamper), 64 (not used), 85 (not
81-88
used), 86 (not used), 87 (not used), 88 (2nd Receiver).
-53-