TABLE 1. AUXILIARY DEVICE CURRENT DRAW WORKSHEET
DEVICE
CURRENT #
uNITs
TOTAL
CURRENT
4127 Console
20
mAt
4137AD Console
60 mAt
5137AD/ADR Console
90 mAt
6127 Console
20 mAt
6137 Console
85 mAt
6139/6139R Console
100 mAt
675 Ground Start Module
50 mA
4281H or 4281M Receiver
40 mA
4219 Zone Expander
30mA
*
*
TOTAL =
(700 mA max.)**
t
only applies if console is powered from Control terminals ❑ & ❑ (12V + and -),
● If using hard-wire devices such as PIRs, refer to the specifications for that particular
unit’s current draw.
● * In UL installations, maximum current draw from the Auxiliary Output and the Alarm
Output combined must not exceed 700 mA.
WIRING INFORMATION FOR CONSOLES, RF RECEIVERS, AND OTHER DEVICES
Maximum Wiring Lengths
If single or multiple units (Consoles, RF Receivers, Zone Expander, etc.) are
When Single or Multiple
connected to a single 4-wire run to the console terminals on the control,
Devices are Connected to a
determine the current drawn by the unit(s) connected to the single
wire run,
Single Wire Run to the
then refer to the Wiring Run chati below to determine the maximum wire length
Console Terminals on the
that can be safely used for each wire size.
Control
In some cases, the total current drawn may result in a value not shown in the
chart. For example, if you intend to use #22 gauge wire and the total current
drawn is 400 mA (a value midway between 300 mA and 500 mA), the
maximum wire length you should use is approximately 65 ft (a length midway
between 50 and 80 feet). Other maximum wire lengths for values of current not
shown in the chart can be calculated in a similar manner.
Maximum wire lengths for a device that is homerun to the control can also be
determined from the chart, based on the current draw of that device alone.
TABLE 2.
WIRING RUN CHART FOR DEVICES* DRAWING POWER FROM THE CONSOLE
TERMINALS ON THE CONTROL (~ &
❑ , 12V+ & Ground Return)
TOTAL CURRENT DRAWN BY ALL UNITS ON A SINGLE WIRE RUN
Wire Size 50 mA or less
100 mA
300 mA
500 mA
700 mA
#22
500 ft
(152m)
250 ft (76m) 80 ft (24m)
50ft(15m) 35ft(10.6m)
#20
750 ft (228.6m)
380 ft (116m) 130 ft (39.6m)
80 ft (24m)
55 ft (16.8m)
#18
1300 ft (396m) 650 ft(198m) 220 ft (67m)
130 ft (39.6m)
100 ft (30.4m)
#16
2000 fl (609.6m)
1000 ft (305m) 330 ft(100.5m)
200 ft (70m)
140 ft (42.7m)
I
MAXIMUM WIRE LENGTH
I
* Includes Remote
Consoles, RF Receivers, and Zone Expander.
Note: The length of all wire runs combined must not exceed 1500 feet when unshielded quad
conductor cable is used (750 feet if shielded cable is used). This restriction is due to the
capacitive effect
on the data lines when quad cable is used.
-28-