*5O SESCOA/Radionica
Enter O if Radionics format is to be used with hexadecimal O-9, B-F reporting.
(1= Ses/!l= Rad)
Enter 1 if SESCOA format is to be used with only numeric reporting (O-9).
NOTE: Selection applies to both primary and secondary phone numbers.
*51 Dual Reporting
Enter 1 if it is desired that all reports are sent to both primary and secondary
(Q=no/1 =yes)
phone numbers. If dual reporting is desired and Ademco High Speed format is to
be
used at all, it must be selected as both the primary and secondary
transmission formats. If
used with Spilt Repotting “1” option (1*34), alarms go to
both primary & secondary numbers, while all other reports go to secondary only.
If used with Split Reporting “2” option, open/close and test messages go to both
lines, while all other reports go to primary.
*52 Standard/Expanded Six l-digit field entries:
Report For Primary Alarm, Restore, Bypass,, Trouble, Open/Close, Low Battery.
Enter Ofor Standard or 1 for Expanded reporting for the primary phone line.
Note: Expanded overrides 4+2 format.
53 Standard/Expanded Six 1-digitfield entries:
Report For Secondary Alarm, Restore, Bypass,, Trouble, Open/Close, Low Battery.
Enter O for standard or 1 for expanded reporting for the secondary phone line
Note: Expanded overrides 4+2 format.
*54 Report Code Digit For
Alarm code digit for 3+1, 4+1, 4+2, and Ademco Express, for a standard report.
Zones 1-8
In High Speed, this digit assigns the reporting channel. For Contact ID, a non-
zero digit enables reporting for the corresponding zone.
55 Report Code ID Digit
ID digit for an expanded 3+1 or 4+1 report, or for a 4+2 or Ademco Express
For Zones 1-8
report. If this ID digit equals O,only 3+1 or 4+1 (or 4+1 Express) non-expanded
messages will be sent. In High Speed or Contact ID format, this field is ignored.
*56
Report Code Digit For See field *54
Zones 9-16
57 Report Code ID Digit
See
field *55
For Zones 9-16
*58 Supervisory & Restore
Five 2-digit field entries:
Codes For Zones 1-16 Alarm Restore, Trouble, Trouble Restore, Bypass, Bypass Restore.
59 Report Code Digit For See field 54
Zones 17-24
%0 Report Code ID Digit See field 55
For Zones 17-24
*61 Report Code Digit For See
field *54
Zones 25-32
62 Report Code ID Digit
See
field 55
For Zones 25-32
%3 Supervisory& Restore
Five 2-digit field entries:
Codes For Zones
Alarm Restore, Trouble, Trouble Restore, Bypass, Bypass Restore.
17-32
%4 Report Code Digit For See
field 54
Zones 33-40
65 Report Code ID Digit
See field *55
For Zones
33-40
%6 Report Code Digit For See field 54
Zones 41-48
%7 Report Code ID Digit
See field 55
For Zones 41-48
-51-