Type 06
24-hour Went Alarm.
Type 07
24-hour Audible Alarm.
Type 08
24-hour Auxiliary
Alarm.
Type 09
Supewised Fire. (No
Verification)
Type 10
interior w/Deiay.
Type 20
Arm-Stay*
Type 21
Arm=Away*
Type 22
Disarm’
Type 23
No Aiarm Response
This zone type sends a report to the Central Station but provides no console
display or sounding. This zone type is usually assigned to a zone containing an
Emergency button.
This zone type sends a report to the Central Station, and provides an alarm sound
at the console, and an audible external alarm. This zone type is usually assigned
to a zone that has an Emergency button.
This zone type sends a report to Central Station and provides an alarm sound at
the console. (No beii output is provided). This zone type is usually
assigned to a zone containing a button for use in personal emergencies, or to a
zone containing monitoring devices such as water sensors, temperature sensors,
etc.
This zone type provides a fire alarm on short circuit and a trouble condition on
open circuit. The beil output will pulse when this zone type is faulted. This zone
type is always active and cannot be bypassed. This zone type can be
assigned to any wired zone, but oniy certain wireiess systems
zones.
This zone type gives entry delay (using the programmed entry time), if tripped
when the panel is armed in the Away mode. This zone type is also active during
maximum mode, but no delay is provided (alarms occur immediately if zone is
tripped). This zone type is bypassed when the panei is armed in the
Stay or instant modes.
Delay begins whenever sensors in this zone are
violated, regardless of whether or not an entry/exit delay zone was tripped first.
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which
will result in arming the system in the STAY
mode
when the zone is activated.
This is a special
purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in arming the system in the
AWAY mode when the zone is activated.
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in disarming the system when
the zone is activated.
This zone type can be used on a zone when an output relay action is desired, but
with no accompanying alarm (ex. lobby door access).
Note that these zone types are not for use by 5700 series devices.
NOTE FOR PANiC KEYS
Keypad panic zones share the same zone response type for all 8 partitions, but
panics may be individually enabled for each partition.
iMPORTANT! FAULT ANNUNCIATION
Polling loop and
RF faults (zones 88-91 & 97) will repori as trouble conditions
only, and as such, should be assigned either zone type 00 if no annunciation is
desired, or zone type 05 if annunciation as trouble condition is desired. See
FAULT ANNUNCIATION notes in POLLING LOOP and WiRELESS EXPANSION
sections for more information.