To ADD a Maater,
Manager or Operator
code
Installer must program at
least one Mastsr cods.
-
Or Master or Manager code,
but must be code with higher
level of authority than the code
being changed. (i.e. Master
code can add a Manager or
Operator level code, but
cannot add another Master
code;
a Manager code can add
an Operator level code, but
cannot add a Master or another
Manager code).
Once there, the current display becomes attached to that partition and status
requests, etc. are now displayed for that partition,
unless a period of 120 seconds
elapses with no key entries.
To return to your original partition, you may enter the
same key sequence and
end if with your normal partition number or “O”. You’re
now back to where you started. It’s that simple! You may view this operation as a ~
big selector switch and you are at the switch at the console.
EXAMPLE: User may be regularly assigned to partition 1. This would be the
default display for this user, however he may “select” to go to partition 2 for
example.
(Assumes he has been programmed for access to partition 2) The user
enters his normal access code and the proper sequence to select another
partition followed by the number 2 for partition 2. The display will now select
partition 2 information for view and further action. In the above example notice
that no access is allowed for this user into partitions 3-8. Attempts to access
these partitions would be denied automatically.
Important!: Duringuser code entry, normal key depressions at other consoles
in a partition will be ignored. However, panic key depression will cause an alarm
and terminate user entry.
Enter Installer Code- + [8]+ new User # (00-99) + new Usets code
Console will prompt for the Authority Level for this user.
EEKl
Emcl
Access Group?
Enter O-8
Enter the level number as follows:
1=
Master (Arm, Disarm, Bypass, add or modify lower
level users)
2 = Manager (Arm, Disarm, Bypass, add or modify lower
level users)
3=
Operator Level A (Arm, Disarm, Bypass)
4= Operator Level B ( Arm, Disarm)
5 = Operator Level C ( Arm, Disarm only if system armed
with this code)
6 = Duress (Arm, Disarm, triggers silent panic alarm)
Console will then prompt for Open/Close reporting option
for this user.
-
Press O(NO) or 1 (YES), depending on whether or
not arming/disarming by this user will trigger opening
& closing reports.
If access schedules have been programmed, this
prompt appears. Enter the user’s access group
number (1-8) if this user should have limited access
to the system. Enter Oif no access group should be
assigned.
If a 5800 series button transmitter has been enabled,
and not assgned to a user, this prompt will appear.
If yes
was given as the answer to the RF button
question, the zone number for the button will be
requested. Enter one of the zone numbers
assigned to the button transmitter as AWAY, STAY
or DISARM. The system will then assign any STAY,
AWAY or DISARM buttons of the transmitter to this
user number..
Press O(NO) or 1 (YES). If NO, the program exits this
mode. If yes, the Console prompts for the Global Arm
option for this user.
Press O (NO) or 1 (YES), depending on whether or
not this user will be allowed to arm more than one
partition via Global Arm prompts (described in the
KEYPAD FUNCTIONS section) .
If the Multi-Access option was selected for this user,
w
the console now prompts for the user’s access to
the next partition.