Primary Power
Back-Up Power
Earth Ground
Connections
Power-Up Procedure
Power to the Control panel is supplied by model No. 1361
Plug-in Transformer
which is rated at 16.5VAC, 40VA. Caution must be taken when wiring this
transformer to the panel to guard against blowing the fuse inside the transformer
(non-replaceable).
NOTE: Use 1361CN Transformer in Canadian installations.
In the event of an AC power loss, the Control panel is supported by a back-up,
rechargeable gel cell battery. YUASA NP4-12 (12V, 4AH) and NP7-12 (12V,
7AH) batteries are recommended. Do not use Gates batteries (sealed
lead-acid type).
The standby battery is automatically tested every 24 hours, beginning 24 hours
after exiting programming mode. In addition, entry into the test mode will cause a
battery test to be initiated.
BATTERY STANDBY TABLE
NOTE: These figures are
~ !g~%~~~
AMP-HRS. “200mA
400mA 600mA 750mA
In order for the lightning transient protective devices in this product to be
effective, the designated earlh ground terminal, must be terminated in a good
earth ground. The following are examples of good eaflh grounds available at most
installations:
w
Metal Cold Water Pipe: Use a non-corrosive metal strap (copper is
recommended) firmly secured to the pipe to which the ground lead is electrically
connected and secured.
AC Power Outlet Ground: Available from 3-prong, 120VAC, power outlets
only. To test the integrity of the ground terminal, use a three-wire circuit tester
with neon lamp indicators, such as the UL-Listed Ideal Model 61-035, or
equivalent, available at most electrical supply stores.
1.
2.
3.
4.
5.
Fill out the Polling Loop Current Draw and Auxiliary Device Current Draw
Worksheets
shown below. Make sure that the currents drawn from these
outputs do not exceed their respective ratings.
CAUTION: Failure to observe the polling loop current rating will cause
polling loop malfunction. Failure to observe the auxiliary output current rating
will result in a battery which does not charge properly or possibly a tripped
circuit breaker.
Wire the 1361 transformer (1361 CN in Canada) to the panel (before
connecting
the battery) as shown in the SUMMARY OF CONNECTIONS
diagram. Do not plug in at this time.
Connect all polling loop and auxiliary devices, such as consoles, PIRs, etc.
Plug the 1361 into an 24 hour, uninterrupted AC outlet. After a few seconds,
the green POWER LED on the console(s) should light and the console(s)
should display “DISARMED READY TO ARM.”
Connect the battery as shown in the SUMMARY OF CONNECTIONS
diagram.
-34-