Trouble:
Rapidly pulsing buzz for a Zone 4 trouble or
for a loss of AC power beyond the programmed
time period.
Entry Warnin,g: Slowly pulsing buzz activated during the entry
delay period subsequent to an alarm or after
disarming subsequent to an alarm.
Key Depression Feedback: Brief buzz for each key depressed.
E. FUNCTIOlUL DESCRIPTIOW, RD. 9787/9789 REMOTE: KEY AAIIICIG STATIOR (See
Diagru 8)
wDlmrrWcyswlkh'
Momentary clockwise turning of the
' key causes AWAY arming
disarming,
trouble and memory of ilarm audible
clearing.
Holding the keyswitch in the clockwise
turned position for a period of 5 seconds,
when attempting to arm AWAY with a
faulted zone, causes forced arming
with automatic shunting of the faulted
zones (if permitted by zone programing).
Rrd LED:
When lit steady, this LED indicates
that the burglary system is armed.
This LED flashes to provide a memory
of alarm indication.
Grwn LED:
When lit, this LED indicates that all
zones are intact and ready for arming.
This LED ironly lit during the disarmed
state.
III.
CamlwICATm OPERATION
The communications capability of the system links it with a monitoring central
station using the telephone switched network.
When alarm, trouble, or status
information is to be communicated, it is translated into a message appropriate
to the format selected via the various PROM options described previously.
The system then seizes the phone line.
A.
Line kialre
A Double Pole Double Throw relay disconnects all extension phones
on this telephone line so that the communicator cannot be blocked
by outgoing calls or by a phone left off hook. The system&n executes
a short 166 second hang-up, to insure a disconnect in case an outgoing
call was being made
, and attempts to establish a communication link.
At this time the PHONE message on the console will light for alarms
not inhibited for this action.
If the system is unsuccessful in
establishing the 'link, an anti-jam procedure is executed if the telco
network used features "called party disconnect."