f)
ALT by 2's (Alternate by Pairs)
This option,
when PROM selected, will cause the communicator
to alternate between the primary receiver and the secondary
receiver while. it is attempting to get through.
It will first
make two attempts to the primary receiver, then two attempts
to the secondary receiver
, and so on until it either receives
a kissoff signal from one receiver or exhausts the maximum number
of attempts.
5. Camnicator Restore Report Enable
If a zone is set up as a restore zone (see control option f14) and
.it is desired to communicate restore, the reporting can be PR@l enabled
for any such zone or zones.
6. &municator Channel
Asstg-t
On the system , each alarm zone, as well as the duress report,may
be assigned a communicator channel.
How the zones are assigned to
channels affects the types of reports that will be sent. As an example,
each zone could be given a different communicator code for unique
zone reporting.
& the zones could be grouped by function with duress
and silent panic zones as Channel (or Code) 1, the fire zone as Channel
(or Code) 2, and the burglary zones as Channel (or Code) 3 (this
would allow the system to be compatible with an existing central
station alarm code scheme).
7. Frunicator Fomat
Individually selectable for primary and Secondary telephone numbers -
Ademco LOW Speed and/or Ademco High Speed, Sescoa, Radionics Superfast.
II.
FURCTIDRU OESCRIPTIDR
A.
FUETIOML DESCRIPTION, ND. 4160-12 C-C@! (See
Diagram 4)
1. suitcbes:
FIRE TEST/RESET Sri tch:
Rightward movement of this momentary
action, center off switch shorts the fire loop to initiate an
al arm.
In addition, the charging current to the battery is
interrupted while this switch is held, giving an indication
of battery condition.
The test is reported to the central station
using the Test code. The fire test is reset by sliding the
switch to the RESET po.sition.
Leftward movement of this switch resets the fire circuit. In
addition, the power to the smoke detectors is interrupted, resetting
any detectors that were activated. Clearing of the fire alarm
memory indication on the console and on the C-CCM requires entry
of the security code and OFF at a console or keypad.
In addition, the fire circuit may be bypassed by holding the
switch to the left f6r 5 seconds.
A fire trouble indication
will be provided when the fire circuit is bypassed.
628-9