Shunt any zone
(permitted by installer programing)
frm a console
OT
a
keypad by entering the security code followed by BYPASS depression
and the number of the zone to be bypassed. The BYPASS LED on the
console will light, the CHK.BYP LED on any remote keypad will light
steady and the zone LED on the C-COM for the bypassed zone will slowly
flash.
'Activate that zone to see if a fault is indicated by the Zone
I.D.
display
at the console, by the READY LED going out at a console, a keypad
or a key arming station or by the zone LED lighting at the C-COM.
t+bne of the above cited displays should indicate the presence of
the zone fault.
Turn the system OFF.
Force an the system.
automatically shunting any purposely faulted
zone (permitted by installer programing),
fram
a
console or a keypad
by entering the security code followed by the arming command (AWAY
or STAY) and the depression of BYPASS or by turning the arm/disarm
key clockwise on a key arming station and holding it for 5 seconds
before allowing it to return to the key removal position. The BYPASS
LED on the console will light, the CHK.BYP LED on any remote keypad
will light steady and the zone LEO on the C-CO?! for the bypassed
zone will slowly flash.
Turn the system OFF.
Am the system from a console
or
keypad and
arming sequence of security code entry plus
or STAY)
by depression of the INSTANT
key.
-_ _ _
Mediately
follow
the
arming command (AWAY
The INSTANT LED on the
console should light.
After allowing for the exit delay to expire,
any fault introduced in the entry/exit zone will cause an imnediate
alarm. Disarm tt# system and note that the INSTANT LED will go out.
Turn on the Chime
Mode by entering the security code followed by
depression of the CHIME key during the disarmed state. Open and
close any contact in zone
1
and a single tone will be produced at
any console or keypad for each fault, announcing the entry of saneone.
Remove the Chime Mode by reentering the security code followed by
depression of the CHIME key.
Conduct a burglary
test (or of any zone if desired) by shorting terminals
W-7
to
TBl-11
during the disarmed state by a N.O. switch or by
jumper. As long as these terminals remain shorted, the system is
in the Test Mode.
It
should be noted, however, that the duration
of the Test Mode is limited to approximately 30 minutes, at which
time the mode will autanatically terminate and the system will return
to the disarmed state (where both fire, if programmed, and panic
alarm capabilities are operative).
In this mode, a momentary fault in any zone will cause a loud single
tone fran the console as well as a l/2 second alarm sound from the
exterior siren or beil.
Al 1 the zone contacts may now
be
clmcked
by Ui sturbing each contact
in each zone and listening for the short siren and/or bell sound
(whichever is used).
628-47
T-7
,:
/)1
724