these terminals.
At the last switch, terminate
the
loop with
the furnished 1000 ohn End-of-Line Resistor.
The zone is PROM programnable for either audible or silent alarm.
A separate PROM progratmning option is whether or not the console
should be inhibited from indicating the silent alarm (e.g. inhibit
for. hold-up but permit indication if used for medical).
Maximum permissible resistance in the zone is 600 ohms (plus
the
1000
ohm End-of-Line Resistor).
This zone has a
normal
response
(250 msec) to activations.
13,14 ZONE 6 Uergey
or Burglary Protection he
This zone may be PROM programned
as
a 24 hour audible EMERGENCY
zone, in which case it provides an additional means to activate
the emergency alarm that can be triggered by simultaneous depression
of the two EMERG keys on the console.
Connect open circuit
momentary switches (e.g. Nos. 219, 273, 4024, 4026) in parallel
across these terminals or closed circuit momentary switches
(e.g. Nos. 273, 4024, 4026) in series with these terminals.
This zone may alternatively be PROM programed as a night burglary
protection zone.
It
has attributes similar to Zones l-3. The
zone is strictly an instant alarm zone (not programmable for
delay). When the zone is programmed for burglary protection,
the EHERG keys on the console are not usable.
The zone has
normal response
(250 nsec) to alarm activations.
At the
last
device, terminate the loop with the furnished
1000
ohm ,End-of-Line Resistor. Maximum permissible resistance in
the zone is 600 ohns (plus the
1000
ohn End-of-Line Resistor).
15
Consol e/Keypad Data Xnput :
This terminal is one of.the four
wire connection points (GREEN) for remote keypads and security
consoles.
Oata entered from the keypads on these units is fed
into the C-COM at this terminal.
16
17
18 Circuit 6round (-) Return
19
Switched Power Output:
This terminal provides a HI output (5
MA. MAX) when comnunication is underway, for control of a listen-
in device or for activation of a remote LED.
20
Circuit Ground (-) Return:
This terminal is one of the four
wire connection points (BLACK) for remote keypads and security
consoles.
Console/Kepad Data Output:
This terminal is one of the four
wire connection points (YELLOW) for remote keypads and security
consoles. Data from the C-CON to activate displays and audible
sounding is fed to the keypads and consoles from this terminal.
6.5 Volt Continuous Power (+) for Powering l&a&e Keypads and
Security Consoles: 675
MA.
MAX.