40–
Section 14. DATA FIELD DESCRIPTIONS
Descriptions of System Data Fields
THE BLANK PROGRAMMING FORM SHOULD BE USED TO RECORD THE DATA FOR THIS INSTALLATION
Defaults (where applicable) Are Indicated In Text
The following pages list all data fields in this control (in numerical order) and serves as a
reference for all data fields in the system.
*
20 INSTALLER CODE 4 | 1 | 1 | 2
The Installer code is used to enter the 4-digit Master security code for
each partition in the normal operation mode, via the keypad connected
to Partition 1. See "Master Code" in the
SYSTEM OPERATION
section
for procedure.
Enter 4 digits, 0–9.
*
21 QUICK ARM ENABLE Partition 1 0 Partition 2 0
0 = do not allow quick arm
1 = allow quick arm (the [#] key can be used instead of the security code
when arming the system).
*
23 FORCED BYPASS FUNCTION Partition 1 0 Partition 2 0
0 = no forced bypass
1 = provide automatic bypass of all open (faulted) zones
All zones bypassed by this function will be displayed after the bypass is
initiated.
UL installations: must be 0 (no forced bypass)
*
25 WIRED ZONE EXPANSION 0
0 = no expander module connected
1 = 4219 connected
2 = 4229 connected
3 = 4204 connected
*
26 CHIME BY ZONE 0
0 = no (chimes on fault of any entry/exit or perimeter zone when chime
mode activated)
1 = yes (chimes on fault of specific zones programmed in relay zone list
3 when chime mode activated)
This option allows the installer to define the specific zones intended to
chime when faulted while the system is in chime mode.
*
27 POWERLINE CARRIER DEVICE (X-10) HOUSE ID 0
Powerline Carrier devices require a House ID. This field identifies this
House ID to the control.
If Powerline Carrier devices are used, they are selected in field
*
80.
House ID is entered in following manner:
0 = A, 1 = B, 2 =C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 = J,
# + 10 = K, # + 11 = L, # + 12 = M, # + 13 = N, # + 14 = O, # + 15 = P.
*
28 PHONE MODULE ACCESS CODE 0 | 0
1-9 = first digit of access code
*
or # = second digit of access code (enter # +11 for "
*
", or # +12 for "#")
The use of a 4285 Phone Module (can be used in Partition 1 only)
requires a 2-digit code.
Example:
If desired access code is 7
*
, 7 is the first entry, and # + 11
(for
*
) is the second entry.
NOTE: A “0” in either digit disables the Phone Module.