Zone Programming — Group 3 Night Set
In programming mode:
The first digit entered is 3 for Night Set.
The second digit is the zone number (1 — 8).
The third digit is the zone type.
Note: The default programming is shown in brackets
in Table 3.4
Example: In Programming Mode press 3 + 2 + 3. This programmes zone 2 as an
Alarm in the Night Set mode and is accompanied by two beeps, indicating
a correct entry.
To review the programming: press the 3 key followed by 00. The zone type is indi-
cated on the keypad zone LEDs (Icon display) for zone 1 (accompanied by one beep),
then zone 2 (accompanied by one beep), etc.
Note: Zone type nine (Fire) is represented by the tamper LED (9) and zone type zero
(Not used) is indicated by the Day LED ().
Zone Programming - Group #1 RF Detectors
This programming group is used to tell the system which zones have wire-free detec-
tors and what the details of those detectors are.
In programming mode:
The first two digits entered are #1 for RF detectors
The third digit entered is the zone number 1-8
The next 9 digits are the RF detector parameters.
For each zone, there are three parameters to be entered, as a total of 9 digits in se-
quence as shown.
tigiDtsriFtigiDdnoceS9ot3stigiD
0(noisivrepuS
)1ro
rebmunpooL
)2ro1(desu
rotcetedehtforebmunlairestigid7ehT
enozsihtotdemmargorpgnieb
Table 3.5 Zone Programming RF Detectors
Example: In Programming Mode press 2 + 2 + 3. This programmes zone 2 as an
Alarm in the Part Set mode and is accompanied by two beeps, indicating a
correct entry.
To review the programming: press the 2 key followed by 00. The zone type is indi-
cated on the keypad zone LEDs (Icon display) for zone 1 (accompanied by one beep),
then zone 2 (accompanied by one beep), etc.
Note: Zone type nine (Fire) is represented by the Tamper LED (9) and zone type
zero (Not used) is indicated by the Day LED ().
teSthgiN
puorG
enoZ
oN
enoZtluafeD
epyT
31 )1(
32 )1(
33 )3(
34 )3(
35 )3(
36 )3(
37 )3(
38 )3(
Table 3.4 Night Set Zones
Vista de página 27