59
Example: To enable the Chime function on zones three and five:
• Enter your User Code.
• Press: 9 3 5.
• Two beeps confirm that the Chime function has been assigned to these zones.
• Zones three and five now have the Chime option enabled.
Disabling the Chime Function on All Zones
To disable the Chime function on all zones, enter your User Code, select the Chime
option by pressing 9, then press the Ö key.
Note: The Chime function cannot be disabled on individual zones. However, the
chime function on a zone is deleted when entering and exiting programming
mode.
Viewing the Event Log from a System Keypad 0
To view the 16 Event Log:
• Enter a valid User Code and press 0.
• The most recently activated zone LED lights (No.) and the keypad beeps once
• The system works its way through the history of the zone activations.
• If a zone has been activated two or more times in succession the zone LED (No.)
will display and the keypad beeps for each activation.
• Hotkey conditions are indicated by all Zone LEDs (scrolling No.s) displaying.
• The keypad beeps twice in rapid succession at the end of the Log display.
The Ö key can be used to terminate event log viewing at any time.
Viewing the Event Log from Ademco Microtech Downloader Software
The Ademco Microtech Downloader software allows the 250 Event Log of the Accord
xpC panel to be viewed. The log stores 250 time and date stamped events.
Viewing the Event Log through the keypad is restricted to the last 16 alarm events
(with no time/date stamp), only by using the Downloader software or a serial printer,
can the full 250 events and the time/date be viewed.
Printing the Event Log
See Appendix B, Connecting a Printer to the System. A Print option is provided in
Group 9 — Option 7 Print Event Log.