ADEMCO VISTA-20HWse Guia de Resolução de Problemas

Consulte online ou descarregue Guia de Resolução de Problemas para Sistemas de segurança - controlo de acesso ADEMCO VISTA-20HWse. ADEMCO VISTA-20HWse Troubleshooting guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 84
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
VISTA-20HWSE
2-PARTITIONED
SECURITY SYSTEM
INSTALLATION
INSTRUCTIONS
®
Principal changes between the VISTA-20HWSE and the
former VISTA-20HW are indicated by margin lines.
N7526-2V2 8/97
Previous Menu
Vista de página 0
1 2 3 4 5 6 ... 83 84

Resumo do Conteúdo

Página 1 - VISTA-20HWSE

VISTA-20HWSE2-PARTITIONEDSECURITY SYSTEMINSTALLATIONINSTRUCTIONS®Principal changes between the VISTA-20HWSE and theformer VISTA-20HW are indicated by

Página 2

–10– Section 2. INSTALLING THE CONTROLThis section provides instructions for mounting the control cabinet, and installingthe cabinet lock (if used).

Página 3 - TABLE OF CONTENTS

–11–Standard Phone Line ConnectionsThe wiring connections shown here are not applicable if the 4285 Phone Moduleis used. Refer to the 4285 Phone Modul

Página 4

–12–b. Wire the other three terminals (Sync, Data, Com) on the 4300 transformer.Wires from these terminals must be connected to a 9-pin connector on t

Página 5 - LIST OF FIGURES

–13– Section 3. INSTALLING REMOTE KEYPADSThis section lists the wired keypads that may be used and provides instructionsfor wiring and mountin

Página 6

–14–3. Connect remote Keypads for Partition 1 to terminals 4, 5, 6, and 7 on thecontrol board, as shown in Figure 6.4. Connect remote Keypads for Part

Página 7

–15–SUPPLEMENTARYPOWER SUPPLY+–CONTROLTERMINAL STRIPAUX AUX. DATA DATA – + IN OUT4567IMPORTANT:MAKE THESE CONNECTIONSDIRECTLY TOSCREW TERMINALS ASSHOW

Página 8

–16– Section 4. BASIC HARD-WIRED ZONES 1–8This section provides general information for the hard-wired zones in the system, plus specificinstructio

Página 9

–17–Turning Off Fire AlarmSoundingYou can turn off Fire alarm sounding by pressing the OFF key on any keypad orother arming/disarming device in that p

Página 10 - INSTALLING THE CONTROL

–18–COMPATIBLE 4-WIRE SMOKE/COMBUSTION DETECTORS1412System Sensor, 4-wire ionization products of combustiondetector2412System Sensor, 4-wire photoelec

Página 11 - ON CONTROL

–19–Programming Hard-Wired ZonesEach zone must be programmed into the system using the *56 ZoneProgramming mode, which assigns characteristics that de

Página 12 - FINAL POWER UP

–2–RECOMMENDATIONS FOR PROPER PROTECTIONThe Following Recommendations For The Location Of Fire And Burglary Detection Devices HelpProvide Proper Cover

Página 13 - POWER UP

–20– Section 5. WIRED ZONE EXPANSIONThis section provides information regarding the use of expansion modules for expanding thenumber of wired zo

Página 14 - PARTITION 2 KEYPADS

–21–Programming Wired Expansion ZonesEach zone must be programmed into the system using the *56 ZoneProgramming mode, which assigns characteristics th

Página 15 - AUX AUX. DATA DATA

–22–ÊÊSection 6.ÊÊÊÊRELAY OUTPUTS & POWERLINE CARRIER ÊDEVICESRelay/Powerline Carrier Device BasicsRelays and Powerline Carrier devices (ex. X-10

Página 16

–23–BRN123456789 1011121234GRNDATA OUTTO CONTROLBLK(–) GROUNDRED(+) 12VYELDATA INFROMCONTROL4321TERMINATE EACHPROGRAMMED ZONEWITH 1000 OHM (1K)END-OF-

Página 17 - System Sensor

–24–Wiring Connections1. Splice one end of a 3-conductor cable to the wire ends of the 4142TR cablesupplied with the 4300 transformer.2. Connect the 4

Página 18

–25– Section 7. 4285 PHONE MODULEThis section provides instructions for mounting and wiring the 4285 PhoneModuleInstalling the Phone ModuleGen

Página 19

–26–Phone Module WiringThe 4285 is wired between the control panel and the premises handset(s). Itlistens for touch tones on the phone line and repor

Página 20 - 1 2 3 4 5

–27–4285 WIRING NOTES:1. Wire the 4285 Phone Module exactly as shown, using a direct-connect cord and RJ31X jack.2. If Touch-tones are not heard when

Página 21

–28–Programming the 4285 Phone ModuleThe system must be programmed for use with the 4285 Phone Module, includingassigning a phone code and selecting w

Página 22 - ÊÊSection 6

–29– Section 8. EXTERNAL SOUNDERSThis section provides a list of compatible sounders and connection information for an externalsounder.Compatible

Página 23 - NO C NC

–3– TABLE OF CONTENTSSection 1. GENERAL DESCRIPTION ...

Página 24

–30–Sounder ConnectionsThe VISTA-20HWSE provides a 12 VDC output which can power external alarmsounders (bells or sirens, see compatible sounders lis

Página 25 - Section 7. 4285 PHONE MODULE

–31– Section 9. LONG RANGE RADIOGeneral InformationCheck availability of Models 7720 PLUS or 7820 long range radios.If output to long range radio

Página 26

–32– Section 10. AUDIO ALARM VERIFICATION (AAV)UNITGeneral InformationAn Audio Alarm Verification (AAV) module, such as the Eagle 1241, is an ad

Página 27 - 4285 WIRING NOTES:

–33–TERMINALS ON CONTROLEARTHGROUND21 22 23 24 25➡1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16PREMISESANSWERINGMACHINE ANDPHONESANSWERING MACHINE▲TIP

Página 28

–34– Section 11. FINAL POWER UPThis section provides information about final power-up procedures and battery size calculations.Earth Ground Conn

Página 29

–35–Making the Battery Connections1. Use the battery standby formula (above) to select the appropriate battery forthe installation.Do not connect the

Página 30

–36– Section 12. MECHANICS OF PROGRAMMINGThis section provides information on how to use the system's programmingmodes. It will enable you to

Página 31 - RADIO DATA IN

–37–3. If the number of digits that you need to enter in a data field is less than themaximum digits available (for example, the phone number field),

Página 32

–38– Section 13.ZONE RESPONSE TYPE DEFINITIONSGeneral InformationYou must assign a zone type to each zone, which defines the way in which thesystem

Página 33

–39–Type 0624-hour Silent AlarmThis zone type sends a report to the Central Station but provides no keypaddisplay or sounding. This zone type is usual

Página 34 - Example:

–4–Section 11. FINAL POWER UP ... 34Earth Gr

Página 35

–40– Section 14. DATA FIELD DESCRIPTIONSDescriptions of System Data FieldsTHE BLANK PROGRAMMING FORM SHOULD BE USED TO RECORD THE DATA FOR THIS IN

Página 36 - 21 QUICK ARM ENABLE

–41–*29 OUTPUT TO LONG RANGE RADIO (No. 7720PLUS/7820) 0 If output to LRR is selected here, all messages that are programmed togo to the primary te

Página 37 - Typical prompt displayed

–42–*36 ENTRY DELAY 02 6| 0 6| 0 00-99 = entry delay time for each partition in secs. Part. 1 Part. 2The system will wait the time e

Página 38 - Section 13

–43–For Fields *43, *44, *45, and*46:Enter digits 0–9; # +11=B; #+12=C; # +13=D; # +14=E; or #+15=F.Enter [*] as the fourth digit if a3-digit account

Página 39 - No entry delay

–44–Pager Report FormatOptions 6-9 send reports to the primary phone number and send reportsto a pager, which has its phone number entered as the seco

Página 40 - SYSTEM OPERATION

–45–TO PROGRAM SYSTEMSTATUS ANDRESTORE REPORTCODES(* 59 Ð* 76, & * 89)Report codes can be programmed using the interactive *56 Zone ProgrammingMo

Página 41 - Part. 1 Part. 2

–46–*60 TROUBLE REPORT CODEÊÊ(See box above) 0 | 0 This will be sent if a zone goes into trouble.*61 BYPASS REPORT CODEÊ (See box above) 0 |

Página 42

–47–*89 EVENT LOG 80% FULL REPORT CODE 0 | 0 If an Event Logging selection is made in field *90, a message can be sentto the central station rece

Página 43

–48–DOWNLOADINFORMATION(*94, *95)*94 DOWNLOAD PHONE NUMBERÊ | | | | | | | | | | | | | | | Enter up to 16 digits as f

Página 44

–49– Section 15. ZONE PROGRAMMING (*56 Menu Mode)While in program mode, press *56 to enter Zone Programming MenuMode.Refer to the zone assignment tab

Página 45

–5–Section 21. SYSTEM OPERATION ... 66Security Cod

Página 46

–50–10 INPUT DEV: LP#AUX WIRE : 1Input Device (In): For the 8 built-in hardwired zones, the Input Devicetypes are automatically displayed

Página 47

–51– Section 16. OUTPUT DEVICE PROGRAMMING (*80Menu Mode)Programming Options DefinedThe following will help you understand the programming of Output

Página 48 - ALPHA DESCRIPTION PROGRAMMING

–52–If a "SYSTEM OPERATION" is chosen (e.g., End of Exit Time),that operation will cause the device to activate as selected in"ACTION.”

Página 49 - (*56 Menu Mode)

–53–Programming Output Relays and Powerline Carrier DevicesWhile in program mode, press *80 to enter Output Device Menu Mode. Thismode is used to prog

Página 50 - 1 00 AW: 1

–54–02 Start: PartAny Partition AEnter (if applicable) the partition number 1 or 2 (or 0 for any).Press the [*] key to continue.02 Stop: Zn ListNo Lis

Página 51 - Menu Mode)

–55– Section 17. ZONE LISTS (*81 Menu Mode)While in program mode, press *81 to enter Zone List Menu Mode. This modeis used to program zone lists for

Página 52 - STOP (STP):

–56–Section 18.ALPHA DESCRIPTOR PROGRAMMINGThis section provides instructions for programming alpha zone descriptors. This is recommendedfor systems u

Página 53

–57–Summary Mode DisplayDefault Descriptor [S ZN 01 ZONE 01If a descriptor was not enteredpreviously for zone 1, the defaultdescriptor for zone 1 wi

Página 54 - 00

–58–S ZN 01 BACKDOOR +Flashing Cursor if “6” ispressed (system ready fornext word). 9. Press Ò6Ó to accept the selectedÊÊword.ÊNOTE: If these

Página 55 - Zone List Displays

–59–Adding Custom Words (will not be annunciated by 4285 Phone Module)You can add up to 10 installer-defined words to the built-in vocabulary. Each of

Página 56 - ALPHA DESCRIPTOR PROGRAMMING

–6–CONVENTIONS USED IN THIS MANUAL MAIN SECTION TITLES ARE SHOWN IN REVERSE TYPEBefore you begin using this manual, it is important that you under

Página 57 - Summary Mode Display

–60–ALPHA VOCABULARY LIST(For Entering Zone Descriptors)NOTE: The list below is a revised vocabulary list which differs from earlier versions of the

Página 58 - S ZN 01 BACK

–61– Section 19. REMOTE PROGRAMMING AND CONTROL (DOWNLOADING)General InformationThe VISTA-20HWSE can be remotely programmed from an IBM compati

Página 59

–62–Remote Programming InformationThe downloading system can perform many functions when in communicationwith the control unit. Besides uploading and

Página 60 - (Word Space)

–63– Section 20. SYSTEM COMMUNICATIONThis section provides an explanation of formats this system accommodates for reporting alarmsand other system

Página 61 - CONTROL (DOWNLOADING)

–64–The following describes each format in greater detail.3+1 and 4+1 Standard Formats Comprise a 3- (or 4-) digit subscriber number and a single digi

Página 62

–65–Ademco Contact ID Reporting takes the following format:CCCC Q EEE GG ZZZwhere: CCCC = Customer (subscriber) IDQ = Event qualifier, where:E = new

Página 63

–66–ÊÊÊSection 21. SYSTEM OPERATIONSecurity CodesInstaller CodeThe installer programs the 4-digit Installer Code initially as part of theprogramming

Página 64

–67–Keypad FunctionsGeneral Information Note that if you enabled QUICK ARM for the partition (field *21), the [#] key canbe pressed instead of enterin

Página 65 - STAY/INSTANT

–68–Panic Keys There are three panic key pairs or (on some keypads) lettered keys that, ifprogrammed, can be used to manually initiate alarms and send

Página 66

–69–Trouble Conditions(See Troubleshooting Guide also)General Information The word "CHECK" on the Keypad's display, accompanied by a ra

Página 67 - Panic Keys

–7– Section 1. GENERAL DESCRIPTIONThe VISTA-20HWSE is a 2-partition control that supports up to 16 zones, using basic hard-wiredand wired expans

Página 68

–70– Section 22. TESTING THE SYSTEMTest ProcedureAfter installation is completed, each partition of the Security System should becarefully tested,

Página 69

–71– Section 23. TROUBLESHOOTING GUIDESYSTEMSYMPTOM POSSIBLE CAUSE REMEDY1. Low Battery message onkeypad.1. "Bat" or “System Lo Bat” (no

Página 70

–72–CONTACTING TECHNICAL SUPPORTPLEASE,Before you call Technical Support, be sure you:¥ READ THE INSTRUCTIONS!¥ Check all wiring connections.¥ Determi

Página 71 - SMOKE DETECTOR

–73–REGULATORY AGENCY STATEMENTSUL NOTICE: This is a "Grade A" residential system.FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENTT

Página 72 - CONTACTING TECHNICAL SUPPORT

–74– Section 24. SPECIFICATIONS & ACCESSORIESSpecificationsVISTA-20HWSE SECURITYCONTROL1. Physical: 12-1/2" W x 14-1/2" H x 3&qu

Página 73 - REGULATORY AGENCY STATEMENTS

–75–6127REMOTE KEYPAD1. Physical: 5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 26mm)2. Electrical: Voltage Input: 12VDC; Current Drain:

Página 74

–76–Accessories (Compatible Devices)No. 1321 16.5VAC, 25VA Plug-In TransformerNo. 4300 Powerline Carrier device Interface AC TransformerSounders Ademc

Página 75

–77–INDEX1-minute delay ... 341011BE12M ...

Página 76

–78–Disarmed, Not Ready ... 67Disarming ...

Página 77

–79–SMARTMODEM 1200 ... 61Sounders ...

Página 78

–8–Security Codes• One installer code for entire system (user 1)• One Master code for each partition (user 2)• 12 secondary user codes for each partit

Página 79

–80–Ð NOTES Ð

Página 80 - Ð NOTES Ð

–81–Ð NOTES Ð

Página 81

–82–WARNINGTHE LIMITATIONS OF THIS ALARM SYSTEMWhile this System is an advanced design security system, it does not offer guaranteed protection agains

Página 82

–83–BLKREDGRNYELAUX. POWEROUTPUT10.5-13.8VDC600mA MAX.INTERRUPTSFOR FIREALARM RESETNOTE:KEYPAD(S) CURRENT (INBOTH PARTITIONS)AND ALLOTHERDEVICESDRAWIN

Página 83 - SE SUMMARY OF CONNECTIONS

N7526-2V2 8/97ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries andaffili

Página 84 - N7526-2V2 8/97

–9–Optional Long Range Radio• Allows all messages that have been programmed to go to the primarytelephone number to be reported additionally to a 7720

Comentários a estes Manuais

Sem comentários