ADEMCO 4140XMPT2 Manual do Utilizador Página 107

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 132
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 106
107
User Codes & Levels Of
Authority (cont.)
Manager (Level 2) Can perform all system functions (Arm, Disarm, Bypass,
etc.) programmed by Master.
May create other users of the system below this level
(Manager cannot assign anybody a level of 0, 1, or 2).
May change his own code.
May add, delete, change operators.
Open/close reporting of added users will be same as his
own (enabled or disabled as assigned by installer or
master).
May operate a partition.
Operator Operators can arm and disarm the system to the authority
(Levels 3-5) assigned, but cannot add or modify any user code.
May operate a partition with one of the three
OPERATOR authority levels A through C listed below.
Level Title Functions Permitted
3 Operator A Arm, Disarm, Bypass
4 Operator B Arm, Disarm
5 Operator C Arm, Disarm only if armed with
same code
Operator C (sometimes known as Baby-sitter code),
cannot disarm the system unless the system was armed
with that code. This code is usually assigned to persons
who may have the need to arm and disarm the system at
specific times only (ex. a baby-sitter needs to control the
system only when baby-sitting).
Duress (Level 6) The duress code is a means of sending a silent alarm to a
central monitoring station if the user is being forced to
disarm (or arm) the system under threat. This feature is
only useful if the system is connected to a central station.
When the system's Auxiliary Voltage Triggers are
connected to another communication's media, note that
duress is signaled on the same trigger that signals silent
panic (whereas duress has its own unique report when
digitally communicated).
The duress code is assigned on a partition by partition
basis and can be any code desired.
When used, the system will disarm (or arm), but will also
send a silent alarm to the central station (if service is
connected). There will be no indication at the console
that an alarm was sent..
Duress Reporting Note: The Duress report triggering
logic activates on the 5th key depression (such as OFF),
not the 4th key depression (last digit of code). Duress
reports will not be triggered if the 5th key is a [*], such as
when performing a GOTO or viewing the capabilities of a
user.
Open/Close Reporting Note: When adding a user, the system will only
prompt for Open/Close report capability if the user is being added by the Installer.
When a Master or Manager adds a new user, the new user's Open/Close
reporting enable will be the same as that of the Master or Manager adding the
user. If Open/Close reports are required to be selectable by the Master or
Manager, the Installer should assign two Master or Manager user codes: one with
Open/Close reporting enabled, and one without Open/Close reporting.
Vista de página 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 131 132

Comentários a estes Manuais

Sem comentários