VOLTAGE TRIGGERS (Connector J7)
(Ground Start Module, Keyswitch, Remote Console Sounder)
General Information Connector J7, located on the right hand side of the main PCB provides 4 trigger
outputs for operating the 675 Ground Start Module, the 4146 Keyswitch, a
remote console sounding piezo, and for triggering auxiliary alarm signaling
equipment. Note that these output triggers can be enabled by partition via
programming field 2*20.
The pin assignments of this connector are shown below. Use only the 4142TR
9-wire cable (available as an option) for making connections to this connector.
1 2 3 4 5 6 7 8 9
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
GROUND
OUT 1
GROUND
OUT 2
GROUND
OUT 3
GROUND
OUT 4
J7 CONNECTOR
OUT 1: GROUND START OR OPEN/CLOSE
OUT 2: FIRE OR KEYSWITCH ARMED LED
OUT 3: BURGLARY/AUDIBLE PANIC/AUXILIARY
OUT 4: SILENT PANIC/DURESS OR KEYSWITCH READY LED
N/U
4142TR CABLE
Output 1 Operates, by default, as a trigger for the 675 ground start
module. This output may optionally be programmed to operate as
an open/close trigger or as a remote console sounder output.
Only one of these options may be used at any time.
Rating: When Activated: 10 - 13.8 VDC through 4K ohms (2.5mA
max)
When De-activated: 100 ohms to ground
Outputs 2 & 4 Operate, by default, as Fire and Silent Panic/Duress triggers
respectively. These triggers may optionally be programmed to act
as Arm and Ready status indicators when it is desired to use the
4146 keyswitch .
Output 2,3 &4 Rating: When Activated: 10 - 13.8 VDC through 5K ohms (2mA
max)
When De-activated: 1k ohms to ground