VISTA-128B Installation Instructions
24-14
01 ACTION ?
none 00
Enter the action code for this timed-event number from the list
at the left. This could be an output command, an arming
command, or any other time-driven event.
Press [
]
to accept the entry. The prompt for the action specifier
will display.
Action Codes: Action Specifier:
01=Relay On
02=Relay Off
03=Relay Close for 2 seconds
04=Relay Close XX minutes
05=Relay Close YY seconds
Actions 01-05
If actions
01-05
were selected, the
prompt at the right will be
displayed. Enter the relay number.
Press [
]
to accept entry. The “Time
Window ?” prompt appears.
01 RELAY # ?
00
06=Relay Group On
07=Relay Group Off
08=Relay Group Close for 2 seconds
09=Relay Group Close XX minutes
10=Relay Group Close YY seconds
Actions 06-10
If actions
06-10
were selected, the
prompt at the right will be
displayed. Enter the relay group
number.
Press [
]
to accept entry. The “Time
Window ?” prompt appears.
01 RELAY GRP # ?
00
Action Codes:
20=Arm-STAY
21=Arm AWAY
22=Disarm
23=Force Arm STAY
24=Force Arm AWAY
40=Enable Open Window by part.
41=Enable Close Window by part.
Actions 21-24 and 40-41
If actions
21-24
or
40-41
were
selected, the prompt at the right
will be displayed. Enter the
partition to which the action
applies. Enter
0
to select all
partitions. Enter a partition number
again to deselect it.
Press [
]
to accept entry. The “Time
Window ?” prompt appears.
PART? 12345678
HIT 0-8 X X
30=Auto bypass - Zone list
31=Auto unbypass - Zone list
Actions 30-31
If actions
30-31
were selected, the
prompt at the right will be
displayed. Enter the zone list
number that contains the zones to
be bypassed or unbypassed.
Press [
]
to accept entry. The “Time
Window ?” prompt appears.
01 ZONE LIST ?
ENTER 1-8 1
42=Enable Access Window for
Access group(s)
Action 42
If action
42
was selected, the
prompt at the right will be
displayed. Enter the group number
to which the time window will
apply.
Press [
]
to accept entry. The “Time
Window ?” prompt appears.
GROUP ? 12345678
HIT 0-8 X