Section 14 – Access Control
14-3
RF buttons and pendants must be assigned to a user number in order to function. See the
User Access Codes section for the procedure.
Wireless Keypads
Wireless keypads (5827 & 5827BD) can provide another way of entering or exiting the
premises. They function the same as alpha keypads, except when the code + # 73 is entered.
This entry will allow momentary access to ALL access points in the partition to which the
keypad is assigned
Programming the Wireless Keypad
Enter the partition the keypad is assigned to in field 1*48.
Using ACS Zone Inputs
If the PassPoint ACS has uncommitted zones, these may be used by the VISTA-128B as
hardwired zones.
Programming the ACS Zone Inputs
1. Enter Zone Programming in #93 Menu Mode.
2. Program this zone as any other zone. Indicate the input type as ACS (10).
3. Enter the PassPoint ACS’s zone ID (00-31).
See Zone Programming in #93 Menu Mode Programming section for a detailed explanation.
Control of Lighting and Appliances
Lighting and appliances can be controlled when an access or exit event occurs. Lights or
appliances can be automatically turned on or off when a valid entry or egress request is
presented at an access point. To control these devices, the VISTA-128B relays or the ACS
relays or triggers are used with keypads and/or rf transmitters whose response type is Access
Point (27).
Programming the Control of Lighting and Appliances
1. Enter Relay Programming in #93 Menu Mode.
2. Program all the information for the relay.
3. Select the relay type: ECP (1) (4204/4204CF), and (2) (X-10).
See Relay Programming in #93 Menu Mode Programming section for a detailed explanation.
Using VISTA-128B Without the VGM and PassPoint ACS
The VISTA-128B can be used for access control without interfacing to PassPoint ACS. A user
can trigger an access point (i.e., door strike) for 2 seconds by entering [User Code] + [0].
Programming the Control for Stand-alone Access Control
1. Enter Relay Programming in #93 Menu Mode.
2. Program the relay type as 1 or 2.
3. For type 1, program the ECP address and relay #.
4. For type 2, program the house and unit codes
5. Program the relay number in field 176 (partition-specific).
See Relay Programming in #93 Menu Mode Programming section for a detailed explanation.