Security Codes Supported
• One Installer code for entire system (user 1)
•One Master code
for entire system
(user 2)
• 12 Secondary User
codes
(users 3–14)
• One Temporary code (user 15)
• One Duress code (user 16).
Temporary Code: A special code that can be used to disarm and arm the system until the Master
code is entered.
Duress Code: An emergency code that, when entered by
any
user to disarm or arm the system,
sends a silent duress message to the Central Station.
Keypad Panic Features
• Up to 3 programmable panic key functions provided
• Designated as zones 95, 96, 99
• Activated by wired and wireless keypads
• Distinguished by subscriber ID number.
Zone Monitor Features
• Provides automatic high loop resistance detection on hardwired zones 2–6, and displays a
CHECK
message for the affected zone when the system is in the disarmed state.
• Contains a Hardwire Short Detection circuit for zones 1-6
†
, and enabled in
✱30.
Detecting a
short in any wired zone, it sends a sensor Trouble message to the Central Station when the
system is in the disarmed state. At the same time a
CHECK
message is displayed on the
keypad.
†
Hardwire Short Detection is disabled on any zone programmed for FIRE (Zone type 09).
Either condition (high resistance or short) detected on any zone, prevents the system from
being armed until the offending condition is cleared. Conversely, when the system is armed,
and these conditions occur, an alarm is generated.
Exit Error False Alarm Prevention Features
• Enables the system to determine the difference between an actual alarm and an alarm
caused by leaving an entry/exit or interior zone open after the Exit Delay expires. If not
disarmed in time, an alarm sounds and an Exit Error report is sent to the Central Station.
An exit alarm condition also occurs if an entry/exit or interior zone re-opens within 2
minutes after the end of an Exit Delay.
•
The system provides an automatic Exit Delay Reset feature that allows the user to exit
(fault), close the door (restore the fault), then re-enter (fault again) the premises within the
exit delay time period. Upon re-entering, a new exit delay time period is begun with the
keypad annunciating three rapid beeps. This feature only resets the exit delay time once
for each arming session.
Optional Output Relays and Powerline Carrier Devices (X10 type)
The VISTA-15/VISTA-15CN
supports the following optional output relays and Powerline
Carrier devices (X10 type):
• Maximum of 4 output devices
• Up to 4 relays using one
4204
Relay Module
• Up to 2 relays using one
4229
Zone/Relay Module
• Up to 4 Powerline Carrier devices (you must subtract the number of relay outputs actually
used by the 4204 or 4229 modules, if used).
Actions are programmable to respond to zone activity or manual keypad entries.
Powerline Carrier devices require the use of the optional 4300 Transformer Module instead of the
supplied 1321/1321CN AC Transformer.