14–1
SECTION 14
Zone Response Type Definitions
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
♦
Zone Type Definitions
••••••••••••••••••••••••••••••••••••••••••••••••••
Zone Type Definitions
You must assign to each zone a zone type, which defines the way in which the system
responds to faults in that zone. Zone types are defined below.
Type 00
Zone Not Used
Program a zone with this zone type if the zone is not used.
Type 01
Entry/Exit Burglary
This zone type provides Exit and Entry Delays whenever the zone
is faulted if the control panel is armed in the AWAY, STAY, or
NIGHT-STAY mode. When the panel is armed in the INSTANT or
MAXIMUM mode, no Entry Delay is provided. Entry Delay #1 is
programmable from 30-240 seconds.
Exit Delay begins whenever the control is armed, regardless of the
arming mode selected, and is independently programmable from
30-240 seconds (field
✱
34).
This zone type is usually assigned to sensors or contacts on doors
through which primary entry and exit take place.
The VISTA-15/VISTA-15CN annunciates faster beeps during the
last 10 seconds of exit delay.
Type 02
Entry/Exit Burglary
This zone type provides a secondary Entry Delay whenever the
zone is faulted if the panel is armed in the AWAY, STAY, or
NIGHT-STAY mode. When the panel is armed in the INSTANT or
MAXIMUM mode, no Entry Delay is provided. Entry Delay #2 is
programmable from 30-240 seconds.
The programmed Exit Delay (field
✱
34) begins whenever the
control is armed, regardless of the arming mode selected.
This zone type is usually assigned to sensors or contacts on doors
through which secondary entry and exit take place, and where
more time might be needed to get to and from the keypad (typically
used for a garage, loading dock, or basement door).
The VISTA-15/VISTA-15CN annunciates faster beeps during the
last 10 seconds of exit delay.
Type 03
Perimeter Burglary
This zone type gives an instant alarm if the zone is faulted when
the panel is armed in the AWAY, STAY, NIGHT-STAY, INSTANT
or MAXIMUM mode. This zone type is usually assigned to all
sensors or contacts on exterior doors and windows.