22–1
SECTION 22
System Operation
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
♦
Security Codes
♦
Keypad Functions
♦
Relay/Powerline Carrier Devices
♦
4285/4286 VIP Module
♦
Exit Error Alarm Displays
♦
Trouble Conditions
♦
Setting the Real-Time Clock
••••••••••••••••••••••••••••••••••••••••••••••••••
Security Codes
Installer Code
The installer programs the 4-digit Installer code initially as part of the programming
procedure. The factory default Installer code is 4-1-1-2, but may be changed in field
✱
20.
The Installer code is the only code that can enter Programming mode. In Normal Operation
mode, it is also used to enter the Master code, which allows access to the normal functions of
the system.
Master Code
In Normal Operation mode,
the Installer code is used to enter the 4-digit Master security
code using
the hardwired connected keypad.
Therefore:
To enter the system's Master code, enter:
[Installer code] + [8] + [0] + [2] + [desired 4-digit Master code]
To change the Master code, enter:
[Master code] + [8] + [0] + [2] + [new Master code] + [new Master code again]
Secondary User Codes
In Normal Operation mode, the Master security code can be used to assign up to 14
Secondary 4-digit security codes, including a Temporary code and a Duress code. The Master
code is also used to remove any Secondary User code(s) from the system (individually).
To assign (or change) a Secondary security code, enter the following on the keypad:
[Master code] + [8] +
User
No.
[(03–16)] + [Secondary User Code]
The system emits a single beep when each secondary code has been successfully entered.
To
delete
a Secondary security code,
enter the following on the keypad
:
[Master code] + [8] +
User No.
[(03–16)]
Temporary User Code:
This user code can only be assigned to User 15 (
[Master code] +
[8] + [1] + [5] + [4-digit Temporary code]
)
on a strictly temporary basis because
whenever
a 4-digit Master code is keyed into the keypad, the existing Temporary code is
removed.
NOTES:
•
All Master and Secondary User security codes permit access to the system for arming,
disarming, etc.
• The Installer code can disarm the system only if it was used to arm it.
• Temporary code (User 15) behaves as Secondary User codes 3 through 14, except that a
keypad entry of a Master code permanently disallows use of this code, and if this code was
not used to arm the system, it cannot be used to disarm the system.
• Duress code is User code No. 16. When this is used to perform any system operation, a
special code is sent to the monitoring station. Instruct users to be careful not to use this
code for normal usage.