ADEMCO Security System VISTA-15CN Guia de Configuração Página 56

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 55
VISTA-15/VISTA-15CN Installation and Setup Guide
13–2
Entering Program Mode
You may use one of the following methods:
a) Press the [
] and [#] keys at the same time within 50 seconds after power is applied to the
control; or
b) After power-up, enter 4 1 1 2 (Installer code) + 8 0 0.
This method is disabled if you exit the Program mode using
98 instead of
99. See the
paragraph titled, "Exiting the Program Mode," later in this section.
If a different Installer code is subsequently programmed, use it instead of 4112 to gain
access to the Programming mode.
When you enter the Program mode, data field
20 is displayed (this is the first data field in
the system). The system now accepts entries for field
20.
Programming a Data Field
1. Press [
]+ Field No. (for example,
21), then make the required entry.
2. When you have completely programmed a data field, the keypad beeps three times and
then automatically displays the next data field in sequence. To go to a different field,
press [
]
plus the desired field number.
3. If the number of digits that you need to enter in a data field is less than the maximum
digits available (for example, the phone number field), enter the desired data, then press
[
] and the next data field number to be programmed.
4. If you try to enter a nonexistent field, the keypad will display EE or ENTRY ERROR.
Simply re-enter [
] plus a valid field number.
Reviewing a Data Field/Erasing an Entry
Press [#] + Field No. Data is displayed for that field number. No changes are accepted in
this mode.
To delete an entry in a field, press [
] + Field No. + [
] (applies only to fields
40-
44,
88,
and
94).
Interactive Mode Programming (
56,
58,
80,
81, and
82)
Typical prompt displayed
during Interactive mode
programming:
Enter Zn Num.
(00 = Quit) 01
Press [
] +
Interactive Mode No.
(for example,
56). The
alpha
keypad
displays the first of a series of prompts requesting
entries.
A detailed procedure (with displays of prompts) is provided in
later sections of this manual.
Zone Number
Interactive Mode Used to Program
56 Zone Programming
Zone characteristics, report codes, alpha
descriptors, and serial numbers
58 Expert Mode
Programming
Zone characteristics, report codes, and
serial numbers.
80 Relay Programming
4204 or 4229 Relay modules, or
Powerline Carrier devices
81 Zone List
Programming
Zone lists for relay/powerline carrier,
cross zone activation, and NIGHT-
STAY Zones
82 Alpha Programming
Zone alpha descriptors
Vista de página 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 131 132

Comentários a estes Manuais

Sem comentários