Section 2 - Installing the Control
2–5
Wiring the AC Transformer
1321/1321CN Transformer
Wire the 1321/1321CN Transformer to terminals 1 and 2 on the control board. See wiring
table below to determine wire gauge.
Use caution
when wiring the transformer to the control panel to guard against blowing the
fuse inside the transformer (the fuse is nonreplaceable).
4300 Transformer
If you are going to use a
4300 Transformer
Interface (required if Powerline Carrier devices
are used), connect the 4300 Transformer’s terminals as follows:
1.
Connect terminals
1, 3 (AC), and 2 (Ground) to control board terminals 1, 2, and 25,
respectively (see
Figure 5
). See
table
below to determine wire gauge to use.
WIRING TABLE
Distance of Transformer
From the Control Panel
Wire Gauge
to Use
Up to 50 feet # 20
50-100 feet # 18
100-250 feet # 16
Wiring to the AC transformer must not exceed 250 feet using 16-gauge wire. The voltage reading
between terminals 1 and 2 of the control must not fall below 16.5VAC, or an
AC LOSS
message is
displayed.
Do not plug the transformer into the AC outlet until you are instructed to do so later in the manual.
2.
Wire the other three terminals (Sync, Data, Com) on the 4300 Transformer. Wires from
these terminals must be connected to a 9-pin connector on the control board (using a
4142TR Cable
supplied with the 4300 Transformer), as shown in
Figure 5
. These
particular wires can be 24-gauge or larger, and can be run along with the AC and ground
wires to the control panel.
123456789
9-PIN CONNECTOR
ON CONTROL BOARD
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
56
125 2
AC
Earth
Ground
AC
Sync
Data
Com
4300 TRANSFORMER/INTERFACE
TERMINALS
ON CONTROL
BOARD
Figure 5. Connections of 4300 Transformer to the Control Board