Section 17 - Output Device Programming
17–3
If a relay is energized before a 4-wire smoke detector is reset, the relay is stopped by the
interruption of Aux.
Power that resets the smoke detector. If this is not desired, supply power to
the relay unit from another 12V power source (e.g., the same source that is powering external
equipment through the relay contacts).
Programming Output Relays and Powerline Carrier Devices
While in Program mode, press ✱
80 to enter Output Device Menu mode. This mode is used to
program all output devices used in the system 4204 or 4229 Relay Modules, or Powerline
Carrier devices). Refer to the Output Device Table for
✱
80 in the separate Programming
Form when programming Output Devices.
NOTE: If you are using Powerline Carrier devices, the House ID of the devices must be
entered in data field
✱27.
After you key in
✱80, the following prompts are displayed.
Output Device Displays
Enter Device No.
(00 = Quit) 01
Enter the Device Number
01
,
02
,
03
, or
04
for a 4204;
01
or
02
for a
4229;
01
–
04
for Powerline Carrier devices; or
00
to end these
entries. Press
[
✱]
to continue.
The
[
✱]
key is used to accept an entry and advance to the next
prompt. The [#] key is used to revert back to the last question to
check or change an entry. Press
[
✱]
to go forward again.
02 A EV ZL ZT -
STT 0 0 0 00 -
This screen displays a summary of the current Device START
programming (for this example, device 02 has been selected).
Press
[
✱]
to continue.
02 A EV ZL ZT -
STP – – 0 00 -
This screen displays a summary of the current Device STOP
programming.
Press
[
✱]
to continue.
02 Device Action
No Response 0
Enter the desired device action as listed below. Press
[
✱]
to
continue.
0 = No response 2 = Stay Closed
1 = Close for 2 seconds 3 = 1 second On/Off
02 Start Event
Not Used 0
Enter the event to START
the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a zone
type/system operation is to be used instead of an event, enter
0
.
Press
[
✱]
to continue.
02 Start: Zn Lst
No List 0
If a zone list is used to START the relay action, enter the zone list
number (to be programmed in field
✱
81):
1
,
2
, or
3
. If not used,
enter
0
. Press
[
✱]
to continue.
02 Start: Zn Typ
Zone Disabled 00
If a zone type or system operation is used to START the device
action, enter the appropriate 2-digit code (see table that follows). If
not, enter
00
.
Press
[
✱]
to continue.