1–1
SECTION 1
Introduction
•••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
Description
Features
•••••••••••••••••••••••••••••••••••••••••••••••••
Description
The VISTA-15/VISTA-15CN is a security system control that supports up to 32 zones,
including six basic hardwired zones (1 through 6) and a maximum of 26 expansion zones.
These expansion zones may include up to eight hardwired zones, or up to 26 wireless zones if
hardwired zones are not used. Three separate keypad-activated zones are also provided.
Features
Basic Hardwired Zones
Provides 6 basic hardwired zones having the following characteristics:
EOLR supervision
supporting
N.O. or N.C. sensors
Programmable response time (10, 350, or 700 milliseconds)
Up to sixteen 2-wire smoke detectors on zone 1
4-wire smoke or heat detectors on zones 2 through 6 (as many as can be powered from
Auxiliary Power on the control).
Optional Expansion Zones (26 total: up to 8 wired with 18 wireless, OR 26 wireless)
Wired Expansion
:
Supports up to 8 additional wired zones using a 4219 Expansion Module or 4229
Expansion/Relay Module. These zones have the following characteristics:
EOLR supervision supporting N.O. or N.C. sensors
300-500mSec normal response with an option for fast (10-15mSec) response on loop A (first
expansion zone).
Wireless Expansion:
Supports up to 26
wireless
zones (fewer if using wired expansion zones).
Requires the use of a
5881 (5882 in Canada)
type RF receiver,
as indicated below:
Receiver Model No. of Zones
5881L/5882L Up to 8
5881M/5882M Up to 16
5881H/5882H Up to 26
Requires the use of 5800 Series Wireless Transmitters.
Remote Keypads
Up to 4 of any of the following keypads may be used in the installation:
Fixed-word keypad: 6128, 6128RF
Alpha keypad: 6139 (2-line alphanumeric display)