ADEMCO 5130XM Manual de Instruções Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 159
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
HARDWARE OVERVIEW 15
- F. WIRELESS DEVICES -
TRANSMITTER
BATTERIES
.
.
5701
5706
H
El
I
0
1
l
5711WM
l
5715WH (white)
or 5715BR (brown)
.
5727
All transmitters use 9 volt batteries. Either Alkaline type or Kodak lithium
batteries may.be used. Lithium batteries should last 4-7 years under normal
use and have a shell life of 7 years. Transmitters will transmit a ‘Low Battev
signal when battery has 30 days of life remaining.
PANIC TRANSMITTER
l
Programmable for either silent or audible 24 hour atann (can be DIP switch
programmed for zones 62 or 63).
PHOTOELECTRIC SMOKE DETECTOR
l
One piece photoelectric smoke detector with built-in transmitter (DIP
switch programmable for zones 48 through 55).
l
Built-in 85 dB piezoelectric alarm sounder
l
Built-in audible low battery warning.
SLIMLINE DOOR/WINDOW TRANSMUTER
l
Can be used with any closed circuit sensor. NOTE: Can be used on any
zone. 1 through 63 but, if programmed for 3247, there will be a 3 minute
lockout between transmissions.
DOOR/WINDOW TRANSMlTTER W/REED SWITCH
. Sfimline doorlwindow transmitter with a built-in reed switch (magnet
included). Can be used with any closed circuit sensor. NOTE: Can be
used on any zone, 1 through 63, but, if programmed from 3247, there
will be a 3 minute lock-out between transmissions.
UNIVERSAL TRANSMITTER
.
DIP switch selectable for fast response, open or closed circuit sensor
usage, and has a tamper protected cover. Use in applications where
open circuit Heat Detectors are needed or where fast response devices
are needed. NOTE: Can be used on any zone, 1 through 63, but, if
programmed from 3247, there will be a 3 minute lock-out between
transmissions.
WIRELESS KEYPAD
l
Wireless keypad that can be used to turn the burglary protection on and
off with built-in panic function, [‘I + [#I, for either a silent or audible 24
hour alarm. There is an LED indication to verify transmission bcated in the
1’1 READY key. (Each time a key is depressed the LED flashes). The
keypad is identified as zone 00 when it transmits low battery messages.
The Panic is identified as 99’.
WIRELESS PASSIVE INFRARED DETECTOR
l
Wireless Dual Element Passive Infrared (PIR). DIP switch programmable
for zones 32 through 47. NOTE: There is a 3 minute lock-out between
transmissions to preserve battery life.
l
Built-in pulse count capability (selectable).
ADEMCO’s VISTA XM SERIES TECHNICAL REFERENCE MANUAL
WWW.DIYALARMFORUM.COM
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 158 159

Comentários a estes Manuais

Sem comentários