36
SYSTEM CONFIGURATION (ZONES)
- E. ZONE EXPANSION COMBINATIONS -
INTRODUCTION
One of the VISTA system’s strengths is flexibility. VISTA permits the use of
homerun hard-wire, polling loop and wireless technologies in any
combination.. The first 9 zones can be efther ail hard-wired. ail wireless (using
a 4280 RF receiver with ALERT iii transmitters), or a combination of both
technologies. Zones 10 through 64 can use either ail polling ioop devices, ail
wireless (RF) devices,or a combination of both technologies.
The selecting of wireless or polling loop zones is programmed in fields 1’18
to 1’25. To enable a zone as a wireless (RF) zone simply enter a “1’ in the
tocation for that zone, as shown:
Ex: SELECT RF (ZONES 1-8)
12345678
01110001
In the above example, zones 2,3,4, and 8 are programmed to be wireless
(RF) zones; zones 1,s. 6 and 7 are hard-wired.
WIRELESS
PERIPHERALS
SMOKE
41520
a
I *
LM@
a &
RPM DEVICES
n POLLtNG LOOP
.
f
RPM RPM
\
b
b
BASIC 9 HARD-WIRED
ZONES
COMBINATION CONFIGURATION:
USING HARDWIRE, P-WIRE POLLING LOOP
AND WIRELESS TECHNOLOGIES
4280
OR
4280-8
RF
RECEIVER
Diagram 13. ZONE EXPANSION COMBINATION CONFIGURATIONS
ADVISORIES
1. Any zone from l-63 can be designated as an RF zone.
2. Be careful when designating RF zones. If you want a zone to be either
hard-wired or on the polling loop, but accidentally enable it as RF, the
system will ignore that zone. RF enable overrides hard-wire!
,-..
ADEMCO’s VISTA Xh4 SERIES TECHNICAL REFERENCE MANUAL
WWW.DIYALARMFORUM.COM