6
LIST OF TABLES
1.
DIP SWlTCH TABLE, POLLING LOOP
DEVICES..
................................................................................ -29
2.
DIP SWITCH TABLE, WIRELESS DEVICES
...........................................................................................
35
3. BATTERY STANDBY TABLE
................................................................................................................
55
4.
CONTACT ID REPORTlNG CODE DEFlNlTlONS
................................................................................... .66
5. LOW SPEED DIGITAL COMMUNICATOR MESSAGE FORMATS..
.........................................................
.70
6.
SUMMARY OF PROGRAMMING COMMANDS
......................................................................................
.73
7.
INDEX TO PROGRAMMING
FIELDS
.....................................................................................................
.74
8. VOCABULARY OF WORDS STORED IN MEMORY
................................................................................
98
9. AUXILIARY CURRENT DRAW WORKSHEET..
......................................................................................
.129
10. POLLING LOOP CURRENT DRAW WORKSHEET..
.............................................................................
.129
1 1 . STANDARD PRE-PROGRAMMED
DEFAULTS.. ........................... . ......................................................
.132
12. STANDARD LOW SPEED 3+1/4+1 PRE-PROGRAMMING..
.................................................................
.143
13. EXPANDED LOW SPEED 3+1&l PRE-PROGRAMMING..
.................................................................
.145
14. ADEMCO HIGH SPEED PRE-PROGRAMMING
....................................................................................
.147
15. 4+2 EXPANDED FORMAT PRE-PROGRAMMING
................................................................................
.149
STEP 1
STEP 2
STEP 3
STEP 4
STEP 6
STEP 6
STEP 7
SEVEN STEPS TO EASY INSTALLATION
The following steps are required to properly install a VISTA XM system:
Become familiar with the system by reading the GENERAL INFORMATION section.
Determine the hardware required for the installation by reviewing section II:
7-Y
HARDWARE OVERVIEW.
Determine the system’s zone configuration and wiring requirements by reviewing
section Ill: ZONE TYPE DEFINITIONS, section IV: SYSTEM CONFIGURATION
(ZONES) and section V: SYSTEM CONFIGURATION (PERIPHERALS). If the
installation is UL rated, check the special UL requirements in section XIII.
Once the wiring is completed, mount the Control and make power connections
following the instructions provided in section VI: MOUNTING PROCEDURES and
section VII:’ POWERING THE SYSTEM.
Learn how the system operates, including security codes and keypad functions by
reading section VIII: SYSTEM OPERATION.
lf the system is to be supervised by a central monitoring station, read section IX:
SYSTEM COMMUNlCATlON for descriptions of reporting formats and a list of
communication programming default tables.
Program the system via the keypad or by downloading from a remote location,
following the instructions in section X: PROGRAMMING THE SYSTEM and section Xl:
DOWNLOADING (if applicable).
Test the system and teach the user how to perform all commands, following the
procedures in section XII: TESTING THE SYSTEM.
If problems occur, refer to section XIV: TROUBLESHOOTING.
ADVlSORtES
Throughout this manual, information that requires special attention is highlighted in
the ADVISORIES paragraphs. This information includes system limitations, caveats
and other information vital to the proper operation of the system. Be sure to read
these paragraphs carefully.
MODEL NUMBERS
Unless otherwise noted, product model numbers listed in this manual refer to
Ademco products.
ADEMCO’s VISTA XM SERIES TECHNICAL REFERENCE Mi NVAL