PROGRAMMING THE SYSTEM 81
KEYSWITCH ARM/DISARM l 15
ENABLE
I
I
(O/l )
COMMENTS: Enter
1
for keyswitch enable: other&se, enter 0.
Requires the use of zone 7 wired bop (zone 7 no longer available as
protectiin zone when used for keyswltch operation).
NOTE: Zone type 10 nust have been entered for Zone 7 in field ‘02.
Reports opening&losing by user #7 ff reporting is enabled in field
‘52. lf this field is enabled (enter
l),
the fire and panic alan voltage
triggers automatically become ARMING and READY status outputs
for support of the Keyswltch LEDs.
MULTIPLE ALARMS
(O/l 1
‘23
I
El
COMMENTS: Enter 1 to enable the system to permit multiile audible
alarms from a protection zone during one armed interval (as opposed
to only one alarm). Enter 0 for only one alarm. Note that multiple
alarm soundings will not occur more frequently than allowed by the
alarm time-out). This selection has no impact on the number of
communication messages transmitted.
DISABLE 4190WH ‘24
TAMPER DETECTION IN
I
I
EXPANSION ZONES lo-64
COMMENTS: Only applicable if No. 4190WH RPMs are used to
TEST INTERVAL
(O/l/2/3)
TEST INITIATION TIME
(01-31)
POWER UP
IN
PREVIOUS STATE
(O/l 1
provide expansion zones. Enter 1 to disable tamper detection.
Enter 0 to enable tamper detection (opening of the 4190WH case).
‘27
II
El
COMMENTS: Enter the test interval as follows:
Enter 0 for no report,
1
for every 12 hours. 2 for every 24 hours or 3 for every 166 hours (1
week). Must be used in conjunction with data fields
l
63 and ‘66
(location 5). This field enables the automatic battery test. At the
interval selected, AC power will be dropped and the battery will be
tested under auxiliary current load for about 10 minutes. It a test
report is desired, enter a test code in field ‘66. location 5..
l
63
rl
ll
COMMENTS: Enter the time in hours from the time that the
programming mode is exited that the first test report shall be
transmltted, and/or first battery test initiated. 00 entry signifies
immediately upon exiting.
01
- 31 represents the range in hours
that can be selected. See field ‘66 for assigning the Test Report
code.
‘26
I
I
COMMENTS: Ente?l if it is desired that upon power-up (after a low-
battery is sensed), the system will assume the system status prior to
power down. Enter 0 if it is desired that the system will atways power
up in a disarmed state. When the system powers up armed, an alarm
will occur 3 minutes after arming if a zone is faulted. When so armed,
reports closing as User #7 if open/close reporting for User #7 was
enabled in Address ‘52.