GENERAL
INFORMATION
TYPE 1
TYPE 2
TYPE 3
e
TYPE 4
TYPE 5
.’
SECTION III
ZONE TYPE DEFINITIONS
SECTION III 19
The VISTA System albws up to 64 zones of hard-wire, polling loop andlor
wireless protection. Each zone must be assigned to a zone type, which
defines the way in which the system responds to faults in that zone. In
addition, there are three keypad activated zones (PANIC keys) identified as
zones 95.96 8 99, a polling bop supervision zone (zone 97) and two RF
supenrisory zones for each 4260 installed (zones 66-92).
ENTRY/EXIT #I
Used for the primary entry/exit route (ex: front door, main entrance). The
zone becomes active when the exit delay time has elapsed. Upon entry
through this zone, the system must be disarmed before the entry delay time
has elapsed or else an alarm will occur. The console will beep multiple times
upon entry (as a retinder to disarm the system).
ENTRY/EXIT #2
Used for a secondary entry/exit route (ex: Garage door, loading dock door,
basement door), where more time might be needed to get to and from the
keypad. The function of this zone type is similar to that of entry/exit #l,
except that the delay times for this zone must be greater than that of #l .
PERIMETER BURGLARY
Used for exterior doors and/or windows which require an instant alarm when
violated.
INTERIOR BURGLARY (FOLLOWER)
Used for areas where an entry delay is required only if an entry/exit delay
zone is faulted first. Usually assigned to zones such as a foyer or lobby
(containing motion detectors) through which users must pass to reach the
keypad to disarm the system. If an entry/exit zone is not faulted first, an
instant alarm occurs upon the faulting of the follower zone. Designed to
provide instant tntrusion alarm in the event an intruder hides on the premises
prior to the system being armed or gains access to the premises through an
unprotected area. This zone will always have the same exit delay time as
programmed for entry/exit #l , and will have the same entry delay time as the
entry/exit delay zone faulted first, entry/exit #l or #2.
DAY/NIGHT BURGLARY
Used for zones which contain a foil-protected door or window (such as in a
store), or to a zone covering a ‘sensitive’ area such as a stock room, drug
supply room, etc., or other controlled access area where immediate
notification of an entry is desired. During the disarmed state (day), the system
will provide latched Console annunciation, rapid beeping, zone ID and
CHECK display, (and central station report, tf desired) of openings or troubles
(such as sensor malfunctions or foil breaks). During the armed state (night),
violations will initiate an alarm, the internal (console) and external (if used)
alarm sounders will activate, and the communicator will report alarms.
ADEMCO’s VISTA XM SERIES TECHNICAL REFERENCE MANUAL