6. Enter Zone DescrIptIona
and Inatalle~a &wage
(5130XMISl37 only)
7. Exlt Progmmmlng Mode
PROGRAMMING THE SYSTk?bi
?3
The 513gXM and 5137 consoles display English language descriptions of
zones. An lnstalle~s message can be programmed to display when the
system is ‘Ready’ to arm (ex. 7HE PETERSON’S READY TO ARM’). The
zone descriptions are programmed by the installer using the built-in
vocabulary of words (see PROGRAMMING ZONE DESCRIPTIONS
paragraphs later In this sectton).
When all fields have been entered and checked, exit programming mode by
pressing either ‘98 or ‘99. A second entry of ‘99 is required If the exit is
being done from fields 1’00 and above. To prevent re-access to
Programming mode using the Installers code, use ‘98. The only way to re-
access Programming mode is by depressing both the r) and I#] keys at the
same time within 30 seconds of power up.
Exiting by using ‘99 always allows
reentry into Programmfng mode using the Installers code. Either way of
exftii will allow access via downloading.
TABLE 6. SUMMARY OF PROGRAMMING COMMANDS
N
COMMANb
ENTER PROGRAMMING MODE: 1. POWER UP, then depress [‘] and [#I at the same time within 30
seconds of powering up. OR
2. Initially, Key: 4 + 1 + 4 + 0 for the 4140XM (or 4+1+3+0 for 4130XM; or
S+1+3+fI for 513OXM) plus CODE key + 0 + 0.
OR
3. After Installer Code is programmed, key: Installer Code + CODE key + 0 + 0.
Type 3 method of re-entry to the programming mode is inhibited if the
programming mode is extted via ‘93.
Type 1 method of entry can always be used. unless console
programming has been locked out by the remote downloader.
ACCESS SECOND SET OF
PROGRAMMING FIELDS
ACCESS FIRST SET OF
PROGRAMMING FIELDS
FROM SECOND SET
ADVANCE TO SPEClFlC FIELD:
PROGRAM A FIELD:
ERASE A FIELD’S CONTENTS:
READ CONTENTS
OF A FIELD:
EXfT PROGRAMMING MODE:
‘94 (once already in the programming mode)
‘99 (if already in second set of programming fields)
r] + ADDRESS (e.g., 01, 10,21, etc.). Take
r] + ADDRESS, followed by data entries.
r] + ADDRESS + r] (only applies to Addresses 31 thru 34, and 90).
[#J + ADDRESS
‘99 (always allows re-entty to programming mode via Type 3 entry
method above), unless console programming has been locked out by
the remote downloader). A second entry of ‘99 is required ff the exit is
being done from fields 1’00 and above.
‘98 (inhibits m-entry to programming mode via Type 3 method). Must be
preceded by an entry of ‘99 H the exit is being done from fields 109 and
above.
RESTORE STANDARD
PRE-PROGRAMMED SEt-llNGS:
Note: When the programming mode is exited, a l-minute set-up period
must elapse before the system can property function.
‘97 (pre-programmed values are shown next to the programming boxes).
ADEMCO’s VISTA Xh4 SERIES TECHNICAL REFERENCE MANUAL